<4. PARAMETER SETTING>
4-6
IM 12E01A06-02E
4.5 Procedures for Setting Parameters
An example for setting parameters, the procedures are described in following modes. For more detail
on the other functions, refer to User’s Manual IM 12E01A06-01E Section 6.
(1) CAL Mode: {CALIB}
(2) HOLD Mode: {HOLD}
(3) RANGE Mode: {*RANGE}
(1)
CAL Mode: {CALIB}
[YES]
F4-4E.ai
[YES]
[NO]
[NO]
[NO]
[YES]
[YES]
[ENT]
[YES]
[ENT]
Self-adjustment
or [ENT]
Self-adjustment
or [ENT]
Self-adjustment
or [ENT]
[YES]
[NO]
[YES]
[ENT]
[YES]
[ENT]
[YES]
[ENT]
Self-adjustment
or [ENT]
Self-adjustment
or [ENT]
[YES]
[ENT]
Self-adjustment
or [ENT]
[NO]
[NO]
[NO]
[NO]
CALIB
X.XXX
STD.CAL
X.XXX
SMP.CAL
X.XXX
ZERO
0.000
VALUE
0.000
VALUE
X.XXX
ZERO
X.XXX
CAL.END
X.XXX
SPAN
X.XXX
SPAN
X.XXX
ZRSPN
0.000
VALUE.Z
0.000
VALUE
X.XXX
ZERO
X.XXX
SPAN
0.000
VALUE.S
X.XXX
SPAN
X.XXX
ZERO
0.000
VALUE
X.XXX
ZERO
X.XXX
SPAN
X.XXX
SPAN
HOLD
Measurement
mode
*1: During the time between [YES] key press on {STD.CAL} display and [YES] or [NO] key press on
{CAL.END} display or on error code display or [MODE] key press to abort, data display shows turbidity
based on sensitivity correction factor (K)=1 and zero correction factor (B)=0. (Value not affected by
SMP.CAL: Display by T1={(S0/(SL/100)}*(V-A), not by T2=K(T1+B))
*2: Span calibration in {STD.CAL} is performed using turbidity standards or check block that has been
selected in CODE16.
*3: In zero calibration, calibration value should be “0.000” and cannot be changed. Only [ENT] key is
accepted to confirm.
*4: In span calibration using check block, calibration value cannot be changed. Only [ENT] key is
accepted to confirm.
*5: First determine the decimal point using [>] key and then set value in the range of 0.000 to 20000 NTU.
*6: Pressing [ENT] key during self-adjustment will abort the procedure, and the turbidity when [ENT] key
is pressed will be used for calibration factor calculation.
*7: Only [YES] key is accepted to confirm.
Note: Calibration factor will be updated when the calibration procedure is completed without cancellation
or errors. If [YES]/[NO] key is pressed on error code display, the instrument goes to {CALIB} display.
Error E203 or E204 appears after the instrument once returns to measurement display.
*1
*2
*3
*4 *5
*7
*6
*6
*6
*6
*6
*6
*5
*5
[
]
[
]
[
]
[
]
*5
*7
[
]
[
]
*5
[
]
[
]
[
]
[
]
Figure 4.2
CAL Mode Flow Chart