4
IM 04L55B01-02EN
MODEL and SUFFIX Codes
GM10
Model Suffix Code Optional
Code
Description
GM10
Data Acquisition Module for S
GM
Type
-1
Standard (max. no. of measurement ch:
100)
-2
Large Memory (max. no. of measurement
ch: 500)
Area
J
General
-
0
Always 0
Optional features
/AH
Aerospace heat treatment
/AS
Advanced security function
8
/BT
Multi-batch function
9
/C3
RS-422/485
/C8
Bluetooth
1
/E1
EtherNet/IP communication
(PLC communication protocol)
3
/E2
WT communication
2
/E3
OPC-UA sever
/E4
SLMP communication (Mitsubishi PLC)
4
/LG
LOG scale
/MC
Communication channel function
5
/MT
Mathematical function (with report
function)
6 7
/PG
Program control
10
1
Regions in which Bluetooth can be used are restricted by the Radio Waves Act of
each country. For details, contact the appropriate authority.
2
If you specify WT communication, you must also specify the communication channel
function (/MC option).
3
If you want to write from a PLC to the GM via EtherNet/IP communication, a
communication channel (/MC) is also required.
4
If you want the GM to load data from SLMP servers via SLMP communication, a
communication channel (/MC) is also required.
5
If you want to load data from other devices into the GM using Modbus client, a
communication channel (/MC) is required.
6
If you want to use the GX90XD or GX90WD pulse input, the /MT option
(computation) is required.
7
If you want to perform pulse integration on GX90XP pulse input modules, the /MT
option (computation) is required.
8
When the advanced security function is set to ON, the scan interval is set to 100 ms
or longer. In addition, the dual interval function and PID modules cannot be used.
9
When the multi-batch function is set to ON, the scan interval is set to 500 ms or
longer. In addition, the dual interval function cannot be used.
10
A PID control module is required to use the program control function.
GM90PS
Model
Suffix Code
Description
GM90PS
Power Supply Module for S
GM
Type
-1
Always –1
Area
N
General
Supply voltage
1
100-240V AC
2
12-28 V DC
1
Power supply connection
D
Power inlet with UL/CSA cable
F
Power inlet with VDE cable
H
Power inlet with GB cable
N
Power inlet with NBR cable
Q
Power inlet with BS cable
R
Power inlet with AS cable
W
Screw terminal (without cable)
-
0
Always 0
1
Only W (Screw terminal (M4)) is available for the power supply connection.
GM90MB
Model
Suffix Code
Description
GM90MB
Module Base for S GM
Type
-01
Always -01
Language
N
General
-
0
Always 0
GX90EX
Model
Suffix Code
Description
GX90EX
I/O Expansion Module
Ports
-02
2 ports
Type
-TP1
Twisted pair cable
-
N
Always N
Area
-N General
I/O module
GX90XA
Model
Suffix Code
Description
GX90XA
Analog Input Module
Channels
-04
4 channels (Type "-H0" only)
-06
6 channels (Type "-R1" only)
-10
10 channels
Type
-C1
Current, scanner type (isolated between
channels)
-L1
DCV/TC/DI (400 VAC, 1 min), Scanner type
(isolated between channels)
-U2
Universal, Solid state relay scanner type
(3-wire RTD b-terminal common)
-T1
DCV/TC/DI, Electromagnetic relay scanner
type (Isolated between channels)
-H0
High-speed universal, individual A/D
(isolation between channels)
-R1
4-wire RTD/resistance, solid state relay
scanner type
-
N
Always N
Terminal type
-3
Screw terminal (M3)
-C
Clamp terminal
Area
N General
GX90XD
Model
Suffix Code
Description
GX90XD
Digital Input Module
Channels
-16
16 channels
Type
-11
Open collector/voltage-free, contact
(shared common), Rated 5 VDC
-
N
Always N
Terminal type
-3
Screw terminal (M3)
-C
Clamp terminal
Area
N General
GX90YD
Model
Suffix Code
Description
GX90YD
Digital Output Module
Channels
-06
6 channels
Type
-11
Relay, SPDT(NO-C-NC)
-
N
Always N
Terminal type
-3
Screw terminal (M3)
Area
N General
GX90WD
Model
Suffix Code
Description
GX90WD
Digital Input/Output Module *
Channels
-0806
Input 8 channels, Output 6 channels
Type
-01
Open collector/voltage-free, contact
(shared common), Rated 5 VDC
Relay, SPDT(NO-C-NC)
-
N
Always N
Terminal type
-3
Screw terminal (M3)
Area
N General
*
Optional code /MT (MATH) required if using the pulse input.