<2. Specifications>
2-5
IM 11M12A01-02E 16th Edition : Mar. 19, 2020-00
l
Model and Codes
Style : S2
Model
Suffix code
Option code
Description
ZR22G
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Separate type Zirconia Oxygen/Humidity Analyzer, Detector
Length
-015
-040
-070
-100
-150
-200
-250
-300
-360
-420
-480
-540
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
0.15 m (for high temperature use) (*1)
0.4 m
0.7 m
1.0 m
1.5 m
2.0 m
2.5 m (*2)
3.0 m (*2)
3.6 m (*2)
4.2 m (*2)
4.8 m (*2)
5.4 m (*2)
Wetted material
-S
-C
- - - - - - - - - -
- - - - - - - - - -
Stainless steel
Stainless steel with Inconel calibration gas tube (*10)
Flange
(*3)
-A
-B
-C
-E
-F
-G
-K
-L
-M
-P
-Q
-R
-S
-W
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
ANSI Class 150 2 RF
ANSI Class 150 3 RF
ANSI Class 150 4 RF
DIN PN10 DN50 A
DIN PN10 DN80 A
DIN PN10 DN100 A
JIS 5K 65 FF
JIS 10K 65 FF
JIS 10K 80 FF
JIS 10K 100 FF
JIS 5K 32 FF (for high temperature use) (*4)
JPI Class 150 4 RF
JPI Class 150 3 RF
Westinghouse
Reference gas
-C
-E
-P
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
Natural convection
External connection (Instrument air) (*11)
Pressure compensated (*11)
Gas Thread
-R
-T
- - - - - - - - - -
- - - - - - - - - -
Rc 1/4
1/4 NPT(Female)
Connection box thread
-P
-G
-M
-T
-Q
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
G1/2
Pg13.5
M20 x1.5 mm
1/2NPT
Quick connect (*9)
Instruction manual
-J
-E
-C
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
Japanese
English
Chinese
—
-A - - - - - - - - - -
Always -A
Options
Valves
Filter
Tag plates
/C
Inconel bolt (*5)
/CV
/SV
Check valve (*6)
Stop valve (*6)
/F1
/F2
Dust Filter (*7)
Dust Guard Protector (*7)
/SCT
/PT
Stainless steel tag plate (*8)
Printed tag plate (*8)
*1
Used with the ZO21P High Temperature Probe Adapter. Select flange (-Q). Only for Oxygen Analyzer.
*2
When installing horizontally the probe whose insertion length is 2.5 meters or 3.0 meters, use the Probe Protector. Be sure to
specify ZO21R-L-200-
□
. Specify the flange suffix code either -C or -K.
*3
The thickness of the flange depends on its dimensions.
*4
Not used in conjunction with -P (pressure compensation) for reference gas. The flange thickness does not conform to JIS
specification
*5
Inconel probe bolts and U shape pipe are used. Use this option for high temperature use (ranging from 600 to 700 °C).
*6
Specify either /CV or /SV option code.
*7
Not used with the high temperature humidity analyzer.
*8
Specify either /SCT or /PT option code.
*9
Not waterproof, avoid rain. Operating maximum temperature is 80°C. Available only in the U.S.
*10 Recommended if sample gas contains corrosive gas like chlorine.
*11 Piping for reference gas must be installed to supply reference gas constantly at a specified flow rate.
Содержание EXAxt ZR22G
Страница 15: ...Blank Page...
Страница 51: ...Blank Page...
Страница 77: ...Blank Page...
Страница 137: ...Blank Page...
Страница 171: ...Blank Page...
Страница 195: ...Blank Page...
Страница 197: ......
Страница 199: ......
Страница 201: ......
Страница 203: ......
Страница 205: ......
Страница 207: ......
Страница 211: ...Blank Page...