59
IM CW500-02EN
Harmonic voltage-current phase difference θk [deg]
Display digits
4 digits
Display range
0.0° to ±180.0°
Equation
c: measurement channel, k: harmonic order
1P2W-1 to 4
θ
1k
,
θ
2k
,
θ
3k
,
θ
4k
,
=
−
sumk
sumk
sumk
P
Q
1
tan
θ
1P3W(3P3W)-1, 2
θ
1k
,
θ
2k
,
=
−
k
sum
k
sum
k
sum
P
Q
1
1
1
1
tan
θ
θ
3k
,
θ
4k
,
=
−
k
sum
k
sum
k
sum
P
Q
2
2
2
1
tan
θ
=
−
sumk
sumk
sumk
P
Q
1
tan
θ
3P3W3A(3P4W)-1
θ
1k
,
θ
2k
,
θ
3k
,
=
−
sumk
sumk
sumk
P
Q
1
tan
θ
Power Supply Quality Measurement Items
Voltage Transient
Measurement
system
Determines the presence of events at approx. 40.96 ksps (24 µs
interval) without gaps (50 Hz/60 Hz)
Display digits
4 digits
Effective input
range
50 V to 2200 V (DC)
Display range
50 V to 2200 V (DC)
Accuracy
0.5% rdg
*
Defined for 1000 V (DC)
Input
impedance
Approx. 1.67 MΩ
Threshold
Specify the absolute peak voltage.
Detection channel (ch)
1P2W-1 to 4
V
1
1P3W-1, 2
V
1
, V
2
3P3W-1, 2
Line voltage
V
12
,
V
32
3P3W3A
Line voltage
V
12
,
V
23
,
V
31
3P4W
V
1
,
V
2
,
V
3
Specifications