4-2
IM CA71-E
4.1 Connecting Cables to Terminals
4.1 Connecting Cables to Terminals
CAUTION
Tighten the output terminal knob by hand.
Do not use a tool or the like. Tightening the knob using a tool or the like
maydamage the terminal, resulting in the disability of normal generation.
Before storing the instrument in the carrying case, tighten the output
terminal knob. If the instrument is stored in the carrying case while the
output terminal knob is not tightened completely and is protruding,
an external force may be applied to the terminal, thus causing damage to
the terminal and resulting in the disability of generation.
Lead cables for
source
(98020)
Black Black
Red
For DC voltage, DC current, thermocouple or pulse output
Step 1:
Connect the red lead cable for source (P/N: 98020) to the H
output terminal and the black lead cable to the L output
terminal.
Step 2:
Connect the two clips of the cables to the input of equipment
under test while making sure the polarities are correct.
For 3-wire connection resistance or RTD signal
Step 1:
Connect the red lead cable for source (P/N: 98020) to the H
output terminal, and both black lead cables to the L output
terminal. (The two black lead cables should be fastened
together to the L output terminals.)
Step 2:
Connect the three leading clips of the cables to the input of
equipment under test while making sure the polarities are
correct.