6-2
IM AQ6380-02EN
Item
Specifications
Environmental conditions
Performance guaranteed temperature range: +20 to +26°C, operating
temperature range: +5 to +35°C, storage temperature range: –10 to
+50°C, ambient humidity: 20 to 80% RH (no condensation), installation
location: indoor use, altitude: 2000 m or less
Safety standards
EN 61010-1, EN60825-1
Overvoltage category II
13
Pollution degree 2
14
Laser
EN 60825-1:2014, IEC 60825-1:2007, GB 7247.1-2012 class 1
Emissions
Compliant
standards
EN 61326-1 Class A
EN 55011 Class A Group 1
EN 61000-3-2
EN 61000-3-3
EMC Regulatory Arrangement in Australia and New Zealand EN 55011
Class A, Group 1
Korea Electromagnetic Conformity Standard (
한국 전자파적합성기준
)
This product is classified as Class A (for use in industrial environments).
Operation of this product in a residential area may cause radio
interference, in which case the user will be required to correct the
interference.
Cable
conditions
• Ethernet connector
Use category 5 or better Ethernet cables.
15
• VIDEO OUT connector
Use a shielded D-sub 15 pin VGA cable.
15
• USB port
Use USB peripherals (e.g., mouse) with shielded USB cables.
15
• GP-IB interface connector
Use a shielded GP-IB cable.
15
Immunity
Compliant
standards
EN 61326-1 Table 2
Influence in the immunity environment (criteria A)
Wavelength measurement accuracy: ±0.1 nm
Cable
conditions
The same as the cable conditions listed above for emissions
Environmental standards
EU RoHS Directive compliant
16
Recommended calibration period
1 year
Unless specified otherwise, 23˚C±3˚C, after warming up for more than an hour, pulse light measurement mode off, high dynamic
range mode off, horizontal scale: wavelength, vertical scale: absolute value level
1 When a 9.5/125 µm single-mode fiber (PC polished) is used, after alignment adjustment and wavelength calibration using the
built-in light source2
Wavelength resolution: ≥0.1 nm
3 Resolution: 0.005 nm, wavelength sampling points: AUTO, excluding sensitivities RAPID1 and NORM_HOLD
4 After resolution calibration using an external light source, at the calibration wavelength. The external light source is a single
vertical mode laser (wavelength: 1520 nm to 1560 nm, peak level: –20 dBm or more, level stability: 0.1 dBpp or less,
wavelength stability: ±0.001 nm or less)
5 TRAD mode: supports CW light and pulse light measurement RAPID mode: supports only CW light measurement
6 Resolution: 0.1 nm, wavelength sampling points: AUTO
7 1523 nm, high dynamic range mode: SWITCH
8 When a HeNe laser (1523 nm) is input, resolution: 0.1 nm, 1520 nm to 1620 nm (excluding peak wavelength ± 2 nm)
9 When a YOKOGAWA single-mode fiber with a standard PC polished connector is used
10 Typical value (Typical value)
11 Some of the AQ6317 series commands may not be compatible depending on the relationship between the target model
specifications and functions.
12 There may be some pixels on the LCD that never light or are always lit (0.002% or less of the total number of pixels including
RGB). These pixels are not defects.
13 The overvoltage category is a value used to define the transient overvoltage condition and includes the rated impulse
withstand voltage. Category II applies to electrical equipment that is powered through a fixed installation, such as a wall outlet
wired to a distribution board.
14 Pollution Degree applies to the degree of adhesion of a solid, liquid, or gas that deteriorates withstand voltage or surface
resistivity. Pollution Degree 1 applies to sealed space (with no pollution or only dry non-conductive pollution). Pollution Degree
2 applies to normal indoor atmospheres (with only non-conductive pollution).
15 Use a cable with a length of 3 m or less.
16 For conformity to environmental regulations and/or standards other than EU, contact your nearest YOKOGAWA office
(PIM113-01Z2).
6.1 Signal Input Section