CONNECTION OF WIRES
WIRING AT INDOOR UNIT AND OUTDOOR UNITS
Open the front cover panel.
Remove screws from electrical box cover and put screws in secured position.
Remove screws from fastener and put screws in secured position.
Prepare wires of right size and grade.
Recommend to use factory-provided wire/cables.
Connected to the terminals following wiring diagrams (terminal or color matches).
Clamp power/control wires to the structure to keep the tension form being transmitted to the wire connection.
Replace screws or fasteners back to where they were.
Note:
Environmental conditions must be taken into consideration when the connections of power cable are made (such
as the ambient temperature, direct exposure to heat, and exposure to sunlight).
The specifications for the power cable refer to the minimum values of the metal core wires, taking into
consideration the voltage losses, the core wire of power cable must be one size larger than the specifications.
The grounding wire must be connected to the indoor units and outdoor units.
The laying of power cables must be done by qualified electricians and comply with the regulations of the local
power supply authorities and with the standards of the electric appliance.
PIPING AND WIRING SIZES IDU to ODU
Model
Liquid /
Gas Line
Min - Max
Length
+/-Elevation
IDU
– ODU Wire
Power/ Control Wire Min.
Recommended HVAC
ODU Circuit Breaker/Fuse
09K
1/4" & 3/8"
10 - 49.2
16.4
4 wire
L1/L2/G (
⏚
), 208-230/1/50 or 60
PV+/PV- 50-350 VDC
– AWG 8/10
20 Amp
12K
1/4" & 1/2
10 - 49.2
16.4
4 wire
L1/L2/G (
⏚
), 208-230/1/50 or 60
PV+/PV- 50-350 VDC
– AWG 8/10
20 Amp
18K
1/4" & 1/2"
10 - 49.2
16.4
4 wire
L1/L2/G (
⏚
), 208-230/1/50 or 60
PV+/PV- 50-350 VDC
– AWG 8/10
20 Amp
24K
1/4" & 5/8"
10 - 49.2
16.4
4 wire
L1/L2/G (
⏚
), 208-230/1/50 or 60
PV+/PV- 50-350 VDC
– AWG 8/10
30 Amp
30K
1/4" & 5/8"
10 - 49.2
16.4
4 wire
L1/L2/G (
⏚
), 208-230/1/50 or 60
PV+/PV- 50-350 VDC
– AWG 8/10
30 Amp
36K
1/4" & 5/8"
10 - 49.2
16.4
4 wire
L1/L2/G (
⏚
), 208-230/1/50 or 60
PV+/PV- 50-350 VDC
– AWG 8/10
30 Amp