LIMITED PRODUCT WARRANTY 

 

Once  the  installation  and  successful  testing  of  the  system  has  been  completely  performed  by  a  qualified 
licensed/certified HVAC technician/contractor, the registration card/form is filled out completely and correctly, mailed 
and filed along with a valid installation invoice from the contractor within 7 days of the original installation, the following 
standard 

Limited Product Warranty 

is qualified: 

10-years

 on the 

compressor

 and 

5-year

 on 

PARTS ONLY

. There 

is 

no labor coverage

 
YMGI  products  are  designed  and  manufactured  free  from  defects  in  workmanship,  and  materials  for  normal  use. 
However, if for any reason, including occasionally transporting between YMGI factories/warehouses and your delivery 
location,  you  discover the  unit has  issues,  YMGI Group  will help field  a solution by following  YMGI’s established 
warranty procedures: 

 
Compressor: 

YMGI will warrant the compressor of a YMGI-validated and approved warranty filing, for a period of 10 

years from the date of successful installation at its original installation location. 

 
Parts: 

YMGI  will  warrant  parts  of  a  YMGI-validated  and  approved  warranty  filing,  for  5  years  from  the  date  of 

successful installation at original installation location. All warranty compressors and parts replaced will become the 
sole  property  of  YMGI Group and must be returned upon request. Warranty parts may be new or refurbished.  All 
parts are tested and approved before shipping. 

 
At no time does YMGI Group warrant labor cost of any type. Warranty will start from the date of a successful 
installation  at  the  original  installation  location,  or  90  days  as  of  original  shipping  date  from  YMGI  Group, 
whichever comes first. 
 
This is a standard limited liability warranty and DOES NOT cover the following: 

 

Any damage or repairs to properties, or persons as an incident of or consequence of improper faulty 
transportation, installation, operation, maintenance or service. 

 

Any damage caused by frozen or broken water hoses or refrigeration pipes in the event of equipment failure. 

 

Any damage due to floods, fire, wind, lightening, accidents, corrosive atmosphere. 

 

Any damage due to interruption or inadequate electrical service to equipment. 

 

Any products that are installed outside the US or Canada. 

 

Any unit that has been moved from its original installation address. 

 

Any labor costs associated with the installation or service of the unit. 

 

Poor unit performance due to improper unit selection (SEER, Unit size). 

 
To validate the above warranties, ALL of the following conditions must all be fulfilled: 

1. The unit was fully (100%) and successfully installed by a licensed or certified HVAC technician. 
2. The unit was installed following all NEC, state and local codes. 
3. The unit was installed following all the information within the Instructions and User Manuals provided by YMGI 

Group. 

4. ALL fields, especially the technician-checklist, of the 

Limited Warranty Registration Card/Form 

were filled out 

completely by the installing technician and signed by both the installing company

’s technician and the unit 

owner. 

5. The 

Limited Warranty Registration Card/Form 

and a copy of the original installing company's invoice have been 

received by YMGI Group-Warranty Dept., POB 1559, O'Fallon, MO 63366, within 7 days of successful installation. 

 
 
 

No warranty filing will be validated or approved, if any one of the above conditions are not met. 

Product registration does not guarantee the validity of this limited warranty statement. 

 
 
 
 
 
 
 

 

Содержание VRFI-07EL-D2B(55)5

Страница 1: ...GI Failure to follow and adhere to all codes and documentation can cause damage to equipment property or even personal injury Installer Must be currently licensed certified HVAC technicians only Must...

Страница 2: ...e to Be Performed 100 By Currently Licensed or Certified HVAC Technicians Contractors 10 Suggestions to Aid You in Hiring an HVAC Contractor 10 Safety Precautions 11 Installation of Indoor Unit 12 Com...

Страница 3: ...d follow them Disposal Notice Do not dispose of this product or its components as unsorted municipal waste as they contain items that may require special treatment Contact your local waste management...

Страница 4: ...red To avoid personal injury or property damage do not disassemble the unit yourself If disassembly is required to check the unit contact your authorized system installer or HVAC professional as they...

Страница 5: ...dations and requirements contained in the following pages and other documents is the first step to help ensure a smooth installation and proper operation of your unit for many years YMGI does not reco...

Страница 6: ...the copper suction line where the indoor unit is located 18 feet or more below the outdoor unit 3 Cross piping and or cross wiring of any units including more than one single zone or a multi zone sys...

Страница 7: ...cable sets to keep from cross piping or cross wiring in multiple zone installations or where pipes for different single zone systems are close to one another 13 Secure the wiring cables that connect b...

Страница 8: ...al shipping date from YMGI Group whichever comes first This is a standard limited liability warranty and DOES NOT cover the following Any damage or repairs to properties or persons as an incident of o...

Страница 9: ...ll ground ship the parts ASAP Expedited shipping is available at the customer s expense 4 Replacement parts that have an approved warranty registration are to be warranted for the remainder of the 5 y...

Страница 10: ...utable 4 Use only a reputable licensed certified HVAC installation professional to prevent any unexpected charges due tof unethical business practices 5 Check their references verify they provide prof...

Страница 11: ...indoor units room temperature too low keeping the temperature difference between indoor and outdoor unit within 41 5 18 YMGI Group recommends that only properly trained and authorized personnel be al...

Страница 12: ...and exhaust have clear paths The unit will not be exposed to direct sunlight The unit is located away from an additional heat source There is no machine oil vapor Cool Warm air can be circulated thro...

Страница 13: ...13 Location for securing the installation pane Schematic drawing of hooks...

Страница 14: ...and vibration may occur depending on how the unit is installed and the environment in which it is used Boring A Wall Hole and Installing the Wall Embedded Pipe For walls containing metal studs or met...

Страница 15: ...ain and flow freely without any backup of water There must not be any type of trap in the drain hose Insert the drain hose to the depth show below so it will not be pulled out of the drain pipe Insula...

Страница 16: ...and Top Casings 1 Remove the 9 screws securing the casings 2 Remove the upper casing by depressing the 2 tabs 3 Remove the left and right casings by depressing the 2 tabs on each side 4 Remove the sli...

Страница 17: ...he mounting plates to the wall with screws 3 Once refrigerant piping and drain piping connections are complete fill in the gap of the through hole with putty A gap can lead to condensation on the refr...

Страница 18: ...ent damage to the flare nuts and gas leaks 2 Align the centers of both flares and tighten the flares Tighten the flare nuts 3 or 4 turns by hand Then full tighten them with the torque wrenches 3 To pr...

Страница 19: ...m 3 8 in O D 12 7mm 1 2 in O D 6 4mm 1 4 in I D 12 15mm 1 2 5 8 in I D 14 16mm 9 16 5 8 in I D 8 10mm 5 16 7 16 in Thickness 0 8mm 1 32 in Thickness 10mm 3 8 in Min Use separate thermal insulation pip...

Страница 20: ...indoor unit install as described in the installation manual supplied with the outdoor unit Lift the sensor securing plate remove the front metal plate cover and connect the wire to the terminal board...

Страница 21: ...s inside the unit Do not branch the power for the drain pump etc from the terminal block Doing so may cause electric shock or fire 1 The power connection cord has been inserted on the mainboard throug...

Страница 22: ...adius as this will damage the pipes Do not over tighten torque the flare nut Over tighten torqueing can cause the flare nut to leak Component Identification 1 Titanium Apatite Photocatalytic Air Purif...

Страница 23: ...e manufacturer or an approved equivalent and installed by a qualified technician to avoid an electrical shock The unit must be installed in accordance with national and local wiring codes An all pole...

Страница 24: ...ng status 5 I FEEL Set I FEEL function 6 TEMP Switch temperature displaying type on the unit s display 7 Set health function and air function 8 LIGHT Set light function 9 X FAN Set X FAN function 10 S...

Страница 25: ...unit on status press button to increase setting temperature and press button to decrease setting temperature The range of temperature is from 16 C to 30 C or 60 8 F to 86 F Note Under AUTO MODE manual...

Страница 26: ...displayed it means the displayed temperature is setting temperature When is displayed it means the displayed temperature is indoor ambient temperature When is displayed it means the displayed tempera...

Страница 27: ...played and time displaying zone resumes to display current time IV Press TOFF button again to cancel timer and OFF is not displayed 2 Setting timer on I Pressing TON button ON is blinking and time dis...

Страница 28: ...e controller should be placed 1m 3 3 away from the TV set or stereo The operation of the remote controller must be performed within its receiving range If you need to control the main unit point the r...

Страница 29: ...front panel into the grooves of the unit 3 places Attach the string to the right inner side of the front grille Close the panel slowly Don t touch the metal parts of the indoor unit as some of the ed...

Страница 30: ...30...

Страница 31: ...e larger and located at the top of the air filter frame and 2 of the 4 are smaller and are located approximately in the middle of the air filter frame 4 Clean or replace the filter 5 When cleaning is...

Страница 32: ...ter Dispose of the old filter as flammable waste Notes Operation with dirty filters 1 Cannot deodorize the air 2 Cannot clean the air 3 Results in poor heating or cooling 4 May cause odor 1 If no drai...

Страница 33: ...hen air conditioning odors or cigarette smoke from the room that were pulled into the unit are being discharged into the tom again Slight bicker was heard when the unit is running This is the sound fo...

Страница 34: ...ping Wiring Ruler Stud Finder Dry Wall Saw Electric Drill 3 Hole Saw Drill Extension Hammer Drill and Bit Measuring Tape Level Flash Light Screw Driver Phillips and Flat Hammer Knife Scissors Goggled...

Страница 35: ...o Date Noes Asked Your Technician for Help Did You Ask YMGI Tech for Help USER NOTES Please list any questions or issues you may have with this unit No Date Installation Company Name Technician Name P...

Страница 36: ...you may have with this unit No Date Contents of Service Maintenance Technician s Company Name Technician Name Phone HCAC License After Sales Service When having quality or other problems when purchas...

Отзывы: