This switch is useful when the remote controller is missing.
15. Signal receiver:
a. It receives signals from the remote controller.
b. When the unit receives a signal, you will hear a short beep.
c. Settings change the beep.
16. Air outlet selection switch.
Before opening the front panel, be sure to stop unit operation and turn the breaker OFF.
Do not touch the metal parts on the inside of the indoor unit, as an injury may result.
If the power supply cord is damaged, it must be replaced by the manufacturer or an approved equivalent
and installed by a qualified technician to avoid an electrical shock.
The unit must be installed in accordance with national and local wiring codes.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be
connected in the fixed wiring.
Working Temperature Range
Indoor side state
Outdoor side state
Dry bulb temp °C(°F)
Wet bulb temp °C(°F)
Dry bulb temp °C(°F)
Wet bulb temp °C(°F)
Rated Cooling
27(80.6)
19(66.2)
35(95)
24(75.2)
Max. cooling
32(89.6)
23(73.4)
43(109.4)
26(78.8)
Min. cooling
21(69.8)
15(59)
18(59)
—
Rated Heating
20(68)
15(59)
7(44.6)
(42.8)
Max. heating
27(80.6)
—
24(75.2)
18(64.4)
Min. heating
20(68)
15(59)
-15(5)
-16(3.2)