YMGI SYMPHONY CHOIR (59)2 EL Series Скачать руководство пользователя страница 8

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World!

 

 

YMGI: Your Modern Green Idea

 

 

LIMITED PRODUCT WARRANTY 

 

Once  the  installation  and  successful  testing  of  the  system  has  been  completely  performed  by  a  qualified 
licensed/certified  HVAC  technician/contractor,  the  registration  card/form  is  filled  out  completely  and  correctly,  and 
filed along with a valid installation invoice from the contractor within 7 days of the original installation, the following 
standard 

Limited Product Warranty 

is qualified: 

7-years

 on the 

compressor

 and 

2-year

 on 

PARTS ONLY

. There 

is 

no labor coverage

 
YMGI  products  are  designed  and  manufactured  free  from  defects  in  workmanship,  and  materials  for  normal  use. 
However, if for any reason, including occasionally transporting between YMGI factories/warehouses and your delivery 
location,  you  discover  the  unit  has  issues,  YMGI  Group  will  help  field  a  solution  by  f

ollowing  YMGI’s  established 

warranty procedures: 

 
Compressor: 

YMGI will warrant the compressor of an YMGI-validated and approved warranty filing, for a period of 7 

years from the date of successful installation at its original installation location. 

 
Parts: 

YMGI  will  warrant  parts  of  an  YMGI-validated  and  approved  warranty  filing,  for  two  years  from  the  date  of 

successful installation at original installation location. 
 
All warranty compressors and parts replaced will become the sole property of YMGI Group and must be returned to 
YMGI  Group  upon  request.  Warranty  parts  may  be  new  or  refurbished.  All  parts  are  tested  and  approved  before 
shipping.

 

At no time does YMGI Group warrant labor cost of any type. Warranty will start from the date of successful 
installation  at  original  installation  location,  or  90  days  as  of  original  shipping  date  from  YMGI  Group, 
whichever comes first. 
 
This is a standard limited liability warranty and DOES NOT cover the following: 

 

Any damage or repairs to properties, or persons as an incident of or consequence of improper faulty 
transportation, installation, operation, maintenance or service. 

 

Any damage caused by frozen or broken water hoses or refrigeration pipes in the event of equipment failure. 

 

Any damage due to floods, fire, wind, lightening, accidents, corrosive atmosphere or any other conditions 
beyond the control of YMGI Group. 

 

Any damage due to interruption or inadequate electrical service to equipment. 

 

Any products that are installed outside the US or Canada. 

 

Any unit that has been moved from its original installation address. 

 

Any labor costs associated with the installation or service of the unit. 

 

Poor unit performance due to improper unit selection (SEER, Unit size). 

 
To validate the above warranties, ALL of the following conditions must all be fulfilled: 

1. The unit was fully (100%) and successfully installed by a licensed or certified HVAC technician. 
2. The unit was installed following all NEC, state and local codes. 
3. The unit was installed following all the information within the Instructions and User Manuals provided by YMGI 

Group. 

4. ALL fields, especially the technician-checklist, of the 

Limited Warranty Registration Card/Form 

were filled 

completely by the installing technician and signed by both the installing company technician and the unit owner. 

5. The 

Limited Warranty Registration Card/Form 

and a copy of the original installing company's invoice have been 

received by YMGI Group-Warranty Dept., POB 1559, O'Fallon, MO 63366, within 7 days of successful installation. 

 
 
 
 

No warranty filing will be validated or approved, if any one of the above conditions are not met. 

Product registration doesn't guarantee the validity of this limited warranty statement. 

 
 
 
 
 
 

Содержание SYMPHONY CHOIR (59)2 EL Series

Страница 1: ...all related documents manuals provided by YMGI Failure to follow and adhere to all codes and documentation can cause damage to equipment property or even personal injury Installer Must be currently li...

Страница 2: ...tallation and Service to Be Performed 100 by Currently Licensed or Certified HVAC Technicians Contractors 11 Suggestions to Aid You in Hiring an HVAC Contractor 11 Safety Precautions 12 System Diagram...

Страница 3: ...rements for handling reclaiming recovering and recycling of certain refrigerants the equipment and tools necessary to perform these service procedures In addition some states or municipalities may hav...

Страница 4: ...stem installer or HVAC professional as soon as possible and provide the following information Data on the unit model number serial number and owner s name A detailed description of the unit s problem...

Страница 5: ...hich the manufacturer may not require certified and licensed personnel to install Reading and following YMGI Group recommendations and requirements contained in the following pages and other documents...

Страница 6: ...ling the piping through any structures at time of installation 2 Not installing an oil P trap in the copper suction line where the indoor unit is located 18 feet or more below the outdoor unit 3 Cross...

Страница 7: ...D or any other identifying marks on each pair of copper lines and wiring cable sets to keep from cross piping or cross wiring in multiple zone installations or where pipes for different single zone s...

Страница 8: ...ation or 90 days as of original shipping date from YMGI Group whichever comes first This is a standard limited liability warranty and DOES NOT cover the following Any damage or repairs to properties o...

Страница 9: ...st will be charged accordingly 3 YMGI will ground ship out the parts ASAP Expedited shipping is available at the customer s expense 4 Replacement parts that have an approved warranty registration are...

Страница 10: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 10...

Страница 11: ...ne if they are reputable 4 Use only a reputable licensed certified HVAC installation professional to prevent any unexpected charges because of unethical business practices 5 Check their references ver...

Страница 12: ...ts 17 While operating in cooling mode do not set the indoor unit s room temperature too low Keeping the temperature difference between indoor and outdoor unit within 41 18 YMGI Group recommends that o...

Страница 13: ...Make sure to disconnect the power supply and switch off all circuits prior to inspecting or servicing the unit Inspecting and servicing the unit while the power supply is connected and the circuits ar...

Страница 14: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 14 System Diagram...

Страница 15: ...e Level Flash Light Screw Driver Phillips and Flat Hammer Knife Scissors Goggled Glasses Mask Gloves Ladder Refrigeration Related Work Flat Surface Wrench Two Flare Nut Tool Set Hex Head Key Set Torch...

Страница 16: ...It receives signals from the remote controller b When the unit receives a signal you will hear a short beep c Settings change the beep Air outlet selection switch Titanium Apatite Photocatalytic Air...

Страница 17: ...are met Both the air intake and exhaust are unobstructed The unit will not be exposed to direct sunlight The unit is located away from an additional heat source s There is no machine oil vapor Cool Wa...

Страница 18: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 18 Location for securing the installation pane Schematic drawing of hooks...

Страница 19: ...t depending on which side of the unit the pipe is taken out For piping see connecting the refrigerant pipe Allow adequate space around the pipe of the indoor unit for easier connection The suggested s...

Страница 20: ...iping For the drain pipe use commercially available rigid polyvinyl chloride general VP 20 pipe with an outer diameter of 26mm or 1 inch and an inner diameter of 20mm or 13 16 inches The drain hose wi...

Страница 21: ...e front panel Remove the 4 screws Remove the front grille while pulling it forward Follow the arrows to disengage the clasps on the front case to remove it Follow the procedure shown when removing the...

Страница 22: ...Do not forget to secure the unit to the wall For wall installations secure the mounting plates using 4 screws and the indoor unit using 4 screws The mounting plates must be installed on a wall capabl...

Страница 23: ...delivered with the unit Never install a drier into this R410A unit as the drying material may dissolve and damage the system and decrease the life expectancy of the unit Poor flaring may cause a refri...

Страница 24: ...The table below shows the recommended dimensions Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal insulation 07 09 class 12 18 class 07 09 class 12 18 class O D 9 52mm 3 8 in O D...

Страница 25: ...e socket until it adheres and seals With a Multi indoor unit install as described in the installation manual supplied with the outdoor unit Lift the sensor securing plate remove the front metal plate...

Страница 26: ...block Doing so may cause electric shock or fire The power connection cord has been inserted on the mainboard through the piping hole of the chassis Please connect the power connection cord with the br...

Страница 27: ...nd wrinkles within the bend radius as this will damage the pipes Do not over tighten torque the flare nut Over tightening torqueing can cause the flare nut to leak Working Temperature Range Indoor sid...

Страница 28: ...cient Green World YMGI Your Modern Green Idea 28 Buttons on Remote Controller 1 ON OFF 2 MINUS 3 PLUS 4 MODE 5 FAN 6 SWING 7 I FEEL 8 FRESH AIR 9 SLEEP 10 TEMP 11 QUIET 12 CLOCK 13 T ON T OFF 14 TURBO...

Страница 29: ...ase set temperature Holding it down above 2 seconds rapidly decreases set temperature In AUTO mode set temperature is not adjustable 3 Press this button to increase set temperature Holding it down abo...

Страница 30: ...er run for one hour the setting temperature will decrease 1 8 F after 2 hours the setting temperature will decrease 2 6 F If the minimal setting temperature is less than 60 8 F then the unit will run...

Страница 31: ...T OFF Press T ON button to initiate the auto ON timer To cancel the auto timer program simply press this button again After pressing this button the icon will disappear and ON blinks 00 00 is displaye...

Страница 32: ...As show in figure NOTE During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m...

Страница 33: ...d in warm water Only neutral detergents should be used After washing the front panel with water dry it with a soft clean cloth Attach the front panel Insert the front panel into the grooves of the uni...

Страница 34: ...remove from the 4 retaining tabs 2 of the 4 tabs are larger and located at the top of the air filter frame and 2 of the 4 are smaller and are located near the middle of the air filter frame Clean or...

Страница 35: ...f paper Do NOT wring out the filter after washing or soaking Filter Replacement When disposing of the old filter treat as flammable waste Issues caused by dirty filters Cannot deodorize the air effect...

Страница 36: ...etween reset mode and standby mode after energizing This function is available without wired controller Standby after energizing Reset after energizing 2 L I Selection between the manual controller an...

Страница 37: ...Sustainable and Efficient Green World YMGI Your Modern Green Idea 37 PROTECTION AND ERROR CODES If an error occurs the error code will be displayed on the indoor unit display wall mounted controller...

Страница 38: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 38...

Страница 39: ...LH Low Air Quality Warning dA Indoor Unit Network Address Error L3 Water Full Protection LC Outdoor Indoor Incompatibility Error dH Wired Controller Circuit Board Error L4 Wired Controller Power Suppl...

Страница 40: ...non Normal or Abnormal The unit doesn t deliver cooling or heating immediately after the unit is restarted remote control or power resuming If the unit is powered off and then restored it will not run...

Страница 41: ...sh sound is heard 2 Bad odor is detected 3 Water is leaking out of the indoor unit 4 Circuit breaker trips or fuse is blown a few times 5 Wires or connections are very hot 6 Oil or refrigerant leakage...

Страница 42: ...nnected Is the circuit protector tripped Is the voltage too high or too low Was the OFF TIMER set on the wireless remote controller The cooling heating effect of the air conditioner is not as expected...

Страница 43: ...Notes Asked Technician for Help Contact YMGI Tech for Help USER NOTES Please list any questions or issues you may have with this unit No Date Installation Company Name Technician Phone HVAC License J...

Страница 44: ...8 16 and 24 Ton Symphony SOLO DC Inverter 57 2 3 Single Zone 16 SEER 09 36K Btu h 58 4 78 1 Single Zone 18 23 SEER 09 36K Btu h Symphony CHOIR DC Inverter 46 2 DC Inverter Multiple Zone 15 SEER 2x09K...

Отзывы: