Safety Precautions 

  

 

1. 

Follow these instructions to complete the necessary installation process. Carefully read this manual before 
installation and unit startup or servicing.   

2. 

Wire size of power cord should be properly sized to meet the required electrical loads. Should the power 
cord get damaged, the power cord should be replaced with a manufacturer approved cable.   

3. 

After connecting the power cord, attach the electric box cover and secure properly.   

4. 

Always meet the nitrogen charge requirements when welding pipes.   

5. 

Never short-circuit or cancel the pressure switch as this will result in damage to the unit.   

6. 

Connect the wired controller before energizing, otherwise the wired controller cannot be used.   

7. 

Before using the unit, verify the piping and wiring are correct. This will avoid water leakage, refrigerant 
leakage, electric shock, or fire etc.   

8. 

Do not insert fingers or objects into the air outlet or inlet grille.   

9. 

Open a door or window for ventilation for allowing fresh air to enter the room to avoid depleting the oxygen 
while gas/oil supplied heating equipment is used during the installation.   

10. 

Never start up or shut off the unit by means of directly plugging into or unplugging the power cord from the 
power outlet.   

11. 

Turn off the unit after it runs at least five minutes, otherwise it will influence the oil return of the 
compressor.   

12. 

Do not allow children to operate this unit.   

13. 

Do not operate this unit with wet hands.   

14. 

Turn off the unit or disconnect the power supply before cleaning the unit. This will avoid possible electric 
shock or personnel injury.   

15. 

Never spray or splash water towards the unit. This can cause a malfunction in the unit or can result in 
electric shock.   

16. 

Do not expose the unit to moist or corrosive environments.   

17. 

While operating in cooling mode, do not set the indoor unit’s room temperature too low. Keeping the 
temperature difference between indoor and outdoor unit within 41

.   

18. 

YMGI Group recommends that only properly trained and authorized personnel be allowed to repair or 
service the unit. Improper repairs or servicing can result in electric shock or fire hazards. Please contact 
YMGI Group if you need help locating a qualified repair or service technician.    

19. 

Before installation, check the power supply to ensure it is sufficient to meet and is in accordance with the 
requirements specified on the nameplate of the unit. Ensure the power overload is functioning correctly 
and make sure it is properly maintained.   

20. 

Installation must be performed only by an authorized installer or HVAC professional in accordance with 
the requirements set by the NEC and CEC. Do not attempt to install the unit yourself. Improper handling 
may result in water leakage, electric shock, fire, and voiding of the warranty.    

21. 

Be sure to use only approved accessories and parts to prevent water leakage, electric shock and fire. 

22. 

Make sure the unit is grounded properly prior to connecting to power source, to avoid electric shock. Do 
not connect the ground wire to a gas pipe, water pipe, lightning rod or telephone line.   

23. 

Energize the unit for 8 hours before operation. Turn off or disconnect the power within 24 hours to prevent 
short-cycling (to protect the compressor).   

24. 

If refrigerant leakage happens in a confined space during installation, ventilate immediately. Poisonous 
gases can occur if the refrigerant gas is exposed to fire.   

25. 

Volatile liquids, such as paint thinners 

or solvents if exposed to the unit’s surface will cause damage to the 

surface finish. Only use a soft cloth along with a mild non-abrasive detergent to clean the outer casing of 
the unit.   

26. 

If the unit does not operate normally or if you notice any type of burning odor, power off the unit and turn 
off the main power supply, then immediately contact your YMGI authorized repair service center or HVAC 
professional.   

 

 

Содержание SYMPHONY CHOIR (59)2 EL Series

Страница 1: ...all related documents manuals provided by YMGI Failure to follow and adhere to all codes and documentation can cause damage to equipment property or even personal injury Installer Must be currently li...

Страница 2: ...tallation and Service to Be Performed 100 by Currently Licensed or Certified HVAC Technicians Contractors 11 Suggestions to Aid You in Hiring an HVAC Contractor 11 Safety Precautions 12 System Diagram...

Страница 3: ...rements for handling reclaiming recovering and recycling of certain refrigerants the equipment and tools necessary to perform these service procedures In addition some states or municipalities may hav...

Страница 4: ...stem installer or HVAC professional as soon as possible and provide the following information Data on the unit model number serial number and owner s name A detailed description of the unit s problem...

Страница 5: ...hich the manufacturer may not require certified and licensed personnel to install Reading and following YMGI Group recommendations and requirements contained in the following pages and other documents...

Страница 6: ...ling the piping through any structures at time of installation 2 Not installing an oil P trap in the copper suction line where the indoor unit is located 18 feet or more below the outdoor unit 3 Cross...

Страница 7: ...D or any other identifying marks on each pair of copper lines and wiring cable sets to keep from cross piping or cross wiring in multiple zone installations or where pipes for different single zone s...

Страница 8: ...ation or 90 days as of original shipping date from YMGI Group whichever comes first This is a standard limited liability warranty and DOES NOT cover the following Any damage or repairs to properties o...

Страница 9: ...st will be charged accordingly 3 YMGI will ground ship out the parts ASAP Expedited shipping is available at the customer s expense 4 Replacement parts that have an approved warranty registration are...

Страница 10: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 10...

Страница 11: ...ne if they are reputable 4 Use only a reputable licensed certified HVAC installation professional to prevent any unexpected charges because of unethical business practices 5 Check their references ver...

Страница 12: ...ts 17 While operating in cooling mode do not set the indoor unit s room temperature too low Keeping the temperature difference between indoor and outdoor unit within 41 18 YMGI Group recommends that o...

Страница 13: ...Make sure to disconnect the power supply and switch off all circuits prior to inspecting or servicing the unit Inspecting and servicing the unit while the power supply is connected and the circuits ar...

Страница 14: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 14 System Diagram...

Страница 15: ...e Level Flash Light Screw Driver Phillips and Flat Hammer Knife Scissors Goggled Glasses Mask Gloves Ladder Refrigeration Related Work Flat Surface Wrench Two Flare Nut Tool Set Hex Head Key Set Torch...

Страница 16: ...It receives signals from the remote controller b When the unit receives a signal you will hear a short beep c Settings change the beep Air outlet selection switch Titanium Apatite Photocatalytic Air...

Страница 17: ...are met Both the air intake and exhaust are unobstructed The unit will not be exposed to direct sunlight The unit is located away from an additional heat source s There is no machine oil vapor Cool Wa...

Страница 18: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 18 Location for securing the installation pane Schematic drawing of hooks...

Страница 19: ...t depending on which side of the unit the pipe is taken out For piping see connecting the refrigerant pipe Allow adequate space around the pipe of the indoor unit for easier connection The suggested s...

Страница 20: ...iping For the drain pipe use commercially available rigid polyvinyl chloride general VP 20 pipe with an outer diameter of 26mm or 1 inch and an inner diameter of 20mm or 13 16 inches The drain hose wi...

Страница 21: ...e front panel Remove the 4 screws Remove the front grille while pulling it forward Follow the arrows to disengage the clasps on the front case to remove it Follow the procedure shown when removing the...

Страница 22: ...Do not forget to secure the unit to the wall For wall installations secure the mounting plates using 4 screws and the indoor unit using 4 screws The mounting plates must be installed on a wall capabl...

Страница 23: ...delivered with the unit Never install a drier into this R410A unit as the drying material may dissolve and damage the system and decrease the life expectancy of the unit Poor flaring may cause a refri...

Страница 24: ...The table below shows the recommended dimensions Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal insulation 07 09 class 12 18 class 07 09 class 12 18 class O D 9 52mm 3 8 in O D...

Страница 25: ...e socket until it adheres and seals With a Multi indoor unit install as described in the installation manual supplied with the outdoor unit Lift the sensor securing plate remove the front metal plate...

Страница 26: ...block Doing so may cause electric shock or fire The power connection cord has been inserted on the mainboard through the piping hole of the chassis Please connect the power connection cord with the br...

Страница 27: ...nd wrinkles within the bend radius as this will damage the pipes Do not over tighten torque the flare nut Over tightening torqueing can cause the flare nut to leak Working Temperature Range Indoor sid...

Страница 28: ...cient Green World YMGI Your Modern Green Idea 28 Buttons on Remote Controller 1 ON OFF 2 MINUS 3 PLUS 4 MODE 5 FAN 6 SWING 7 I FEEL 8 FRESH AIR 9 SLEEP 10 TEMP 11 QUIET 12 CLOCK 13 T ON T OFF 14 TURBO...

Страница 29: ...ase set temperature Holding it down above 2 seconds rapidly decreases set temperature In AUTO mode set temperature is not adjustable 3 Press this button to increase set temperature Holding it down abo...

Страница 30: ...er run for one hour the setting temperature will decrease 1 8 F after 2 hours the setting temperature will decrease 2 6 F If the minimal setting temperature is less than 60 8 F then the unit will run...

Страница 31: ...T OFF Press T ON button to initiate the auto ON timer To cancel the auto timer program simply press this button again After pressing this button the icon will disappear and ON blinks 00 00 is displaye...

Страница 32: ...As show in figure NOTE During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m...

Страница 33: ...d in warm water Only neutral detergents should be used After washing the front panel with water dry it with a soft clean cloth Attach the front panel Insert the front panel into the grooves of the uni...

Страница 34: ...remove from the 4 retaining tabs 2 of the 4 tabs are larger and located at the top of the air filter frame and 2 of the 4 are smaller and are located near the middle of the air filter frame Clean or...

Страница 35: ...f paper Do NOT wring out the filter after washing or soaking Filter Replacement When disposing of the old filter treat as flammable waste Issues caused by dirty filters Cannot deodorize the air effect...

Страница 36: ...etween reset mode and standby mode after energizing This function is available without wired controller Standby after energizing Reset after energizing 2 L I Selection between the manual controller an...

Страница 37: ...Sustainable and Efficient Green World YMGI Your Modern Green Idea 37 PROTECTION AND ERROR CODES If an error occurs the error code will be displayed on the indoor unit display wall mounted controller...

Страница 38: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Your Modern Green Idea 38...

Страница 39: ...LH Low Air Quality Warning dA Indoor Unit Network Address Error L3 Water Full Protection LC Outdoor Indoor Incompatibility Error dH Wired Controller Circuit Board Error L4 Wired Controller Power Suppl...

Страница 40: ...non Normal or Abnormal The unit doesn t deliver cooling or heating immediately after the unit is restarted remote control or power resuming If the unit is powered off and then restored it will not run...

Страница 41: ...sh sound is heard 2 Bad odor is detected 3 Water is leaking out of the indoor unit 4 Circuit breaker trips or fuse is blown a few times 5 Wires or connections are very hot 6 Oil or refrigerant leakage...

Страница 42: ...nnected Is the circuit protector tripped Is the voltage too high or too low Was the OFF TIMER set on the wireless remote controller The cooling heating effect of the air conditioner is not as expected...

Страница 43: ...Notes Asked Technician for Help Contact YMGI Tech for Help USER NOTES Please list any questions or issues you may have with this unit No Date Installation Company Name Technician Phone HVAC License J...

Страница 44: ...8 16 and 24 Ton Symphony SOLO DC Inverter 57 2 3 Single Zone 16 SEER 09 36K Btu h 58 4 78 1 Single Zone 18 23 SEER 09 36K Btu h Symphony CHOIR DC Inverter 46 2 DC Inverter Multiple Zone 15 SEER 2x09K...

Отзывы: