YMGI M2 SERIES Скачать руководство пользователя страница 9

BRIEF UNIT INFO

BRIEF UNIT INFO

P16 OF 44

P15 OF 44

ENGINEERING SUBMITTAL-UNIT SIZES & WEIGHT

UNIT SIZES AND WEIGHT

Check nameplates on both indoor and outdoor units to apply the correct electric power input into each unit.

Check and evaluate the security of the position and structure where the indoor and outdoor units are to be 
installed. All equipment, duct, refrigerant pipe, drainage pipe, electrical panel, and other components to be sturdy 
enough and well integrated to allow the whole HVAC system to perform its job safely and economically as 
supposed.

Refer to the dimensions and weight as shown in the following table.

K But/h

09

12

18

24

30

36

Net Weight (LB)

Indoor/Outdoor

17/61

25/87

33/101

42/123

42/136

42/176

41x12x8

49x13x9

49x13x9

49x13x9

Indoor Unit

WxHxD (Inch)   (ROUNDED) 

Outdoor Unit

31x21x13

33x24x14

32x28x15

35x31x17

35x31x15

33x48x15

 Physical Sizes/weight-Single Zone

 (Subject to Change for Continuous Improvement without Prior Notice)

K But/h

2x09

2x12

2x18

2x24

2x30

Indoor Unit

31x11x7

36x11x8

41x12x8

49x13x9

49x13x9

WxHxD (Inch)   (ROUNDED)  

Outdoor Unit

33x28x15

35x31x17

33x48x15

37x49x17

37x49x17

Net Weight (LB)

Indoor/Outdoor

2x17/112

2x25/135

2x33/200

2x42/229

2x42/257

 Physical Sizes/weight-Dual Zone 

(Subject to Change for Continuous Improvement without Prior Notice)

31x11x7

36x11x8

WxHxD (Inch)

 

   (ROUNDED) 

K But/h

3x09

3x12

3x18

2x09+12

2x09+18

2x12+18

2x12+24

2x12+30

2x18+24

Indoor

31x11x7

36x11x8

31x11x7/36x11x8

31x11x7/41x12x8

36x11x8/41x12x8

36x11x8/49x13x9

36x11x8/49x13x9

41x12x8/49x13x9

Outdoor

33x48x15

37x49x15

33x48x15

33x48x15

33x48x15

37x49x17

Net Weight (LB)

Indoor/Outdoor

3x17/200

3x25/216

3x33/222

2x17, 25/200

2x17, 33/222

2x25, 33/233

2x25, 42/240

2x25, 42/240

2x33, 44/265

Physical -Triple 

Zone

 (Subject to Change for Continuous Improvement without Prior Notice)

Sizes/weight

WxHxD (Inch)

 

   (ROUNDED) 

K But/h

4x09

4x12

3x09+12

3x12+09

2x(09+12)

Indoor

31x11x7

36x11x8

31x11x7/36x11x8

36x11x8/31x11x7

31x11x7/36x11x8

Outdoor

33x48x15

37x49x17

Net Weight (LB)

Indoor/Outdoor

4x17/200

4x25/216

3x20, 35/233

2x35, 20/265

2x(20+35)/240

Physical -Quad 

Zone 

(Subject to Change for Continuous Improvement without Prior Notice)

Sizes/weight

UNIT SIZES AND WEIGHT

41x12x8

MINI WALL MOUNT SYSTEMS-MODELS

Wall Mount Mini Split - Single Zone

Cooling Only

System Model

WMMS-09K-31A(B)

WMMS-12K-31A(B)

WMMS-18K-31B

WMMS-24K-31B

WMMS-30K-31B

WMMS-36K-31B

      Indoor Unit

WMMS-09E-31A(B)

WMMS-12E-31A(B)

WMMS-18E-31B

WMMS-24E-31B

WMMS-30E-31B

WMMS-36E-31B

Outdoor Unit

WMMS-09C-31A(B)

WMMS-12C-31A(B)

WMMS-18C-31B

WMMS-24C-31B

WMMS-30C-31B

WMMS-36C-31B

Heat Pump

System Model

WMMS-09K-32A(B)

WMMS-12K-32A(B)

WMMS-18K-32B

WMMS-24K-32B

WMMS-30K-32B

WMMS-36K-32B

Indoor Unit

WMMS-09E-32A(B)

WMMS-12E-32A(B)

WMMS-18E-32B

WMMS-24E-32B

WMMS-30E-32B

WMMS-36E-32B

Outdoor Unit

WMMS-09C-32A(B)

WMMS-12C-32A(B)

WMMS-18C-32B

WMMS-24C-32B

WMMS-30C-32B

WMMS-36C-32B

Heat Pump

/ Elec. Heat

System Model

WMMS-09K-34B

WMMS-12K-34B

WMMS-18K-34B

WMMS-24K-34B

WMMS-30K-34B

WMMS-36K-34B

      Indoor Unit

WMMS-09E-34B

WMMS-12E-34B

WMMS-18E-34B

WMMS-24E-34B

WMMS-30E-34B

WMMS-36E-34B

Outdoor Unit

WMMS-09C-32B

WMMS-12C-32B

WMMS-18C-32B

WMMS-24C-32B

WMMS-30C-32B

WMMS-36C-32B

Wall Mount Mini Split - Dual Zone

Cooling Only

System Model

      Indoor Unit

Outdoor Unit

Heat Pump

System Model

Indoor Unit

Outdoor Unit

Heat Pump

/ Elec. Heat

System Model

      Indoor Unit

Outdoor Unit

WMMS-2X09K-31B

WMMS-0912K-31B

WMMS-2X12K-31B

WMMS-2X18K-31B

WMMS-2X-24K-31B

WMMS-2X30K-31B

WMMS-09E(F)-31B

WMMS-09/12E(F)-31B

WMMS-12E(F)-31B

WMMS-18E(F)-31B

WMMS-24E(F)-31B

WMMS-30E(F)-31B

WMMS-2X09C-31B

WMMS-0912C-31B

WMMS-2X12C-31B

WMMS-2X18C-31B

WMMS-2X24C-31B

WMMS-2X30C-31B

WMMS-2X09K-32B

WMMS-0912K-32B

WMMS-2X12K-32B

WMMS-2X18K-32B

WMMS-2X24K-32B

WMMS-2X30K-32B

WMMS-09E(F)-32B

WMMS-09/12E(F)-32B

WMMS-12E(F)-32B

WMMS-18E(F)-32B

WMMS-24E(F)-32B

WMMS-30E(F)-32B

WMMS-2X09C-32B

WMMS-0912C-32B

WMMS-2X12C-32B

WMMS-2X18C-32B

WMMS-2X24C-32B

WMMS-2X30C-32B

WMMS-2X09K-34B

WMMS-0912K-34B

WMMS-2X12K-34B

WMMS-2X18K-34B

WMMS-2X24K-34B

WMMS-2X30K-34B

WMMS-09E(F)-34B

WMMS-09/12E(F)-34B

WMMS-12E(F)-34B

WMMS-18E(F)-34B

WMMS-24E(F)-34B

WMMS-30E(F)-34B

WMMS-2X09C-32B

WMMS-09/12C-32B

WMMS-2X12C-32B

WMMS-2X18C-32B

WMMS-2X24C-32B

WMMS-2X30C-32B

Wall Mount Mini Split - Triple Zone

Cooling Only

System Model

      Indoor Unit

Outdoor Unit

Heat Pump

System Model

Indoor Unit

Outdoor Unit

Heat Pump

/ Elec. Heat

System Model

      Indoor Unit

Outdoor Unit

WMMS-3X09K-31B

WMMS-3X12K-31B

WMMS-2X0912K-31B WMMS-2X-1218K-31B WMMS-2X1824K-31B

WMMS-1230K-31B

WMMS-09E(F)-31B

WMMS-09E(F)-31B

WMMS-09/12E(F)-31B WMMS-12/18E(F)-31B WMMS-18/24E(F)-31B WMMS-12/30E(F)-31B

WMMS-3X09C-31B

WMMS-3X12C-31B

WMMS-2X0912C-31B WMMS-2X1218C-31B WMMS-2X1824C-31B WMMS-2X1230C-31B

WMMS-3X09K-32B

WMMS-3X12K-32B

WMMS-2X0912K-32B WMMS-2X1218K-32B WMMS-2X1824K-32B WMMS-2X1230K-32B

WMMS-09E(F)-32B

WMMS-09E(F)-32B

WMMS-09/12E(F)-32B WMMS-12/18E(F)-32B WMMS-18/24E(F)-32B WMMS-12/30E(F)-32B

WMMS-3X09C-32B

WMMS-3X12C-32B

WMMS-2X0912C-32B WMMS-2X1218C-32B WMMS-2X1824C-32B WMMS-2X1230C-32B

WMMS-3X09K-34B

WMMS-3X12K-34B

WMMS-2X0912K-34B WMMS-2X1218K-34B WMMS-2X1824K-34B WMMS-2X1230K-34B

WMMS-09E(F)-34B

WMMS-09E(F)-34B

WMMS-09/12E(F)-34B WMMS-12/18E(F)-34B WMMS-18/24E(F)-34B WMMS-12/30E(F)-34B

WMMS-3X09C-32B

WMMS-3X12C-32B

WMMS-2X0912C-32B WMMS-2X1218C-32B

WMMS-2X1824-32B

WMMS-2X1230C-32B

Cooling Only

System Model

      Indoor Unit

Outdoor Unit

Heat Pump

System Model

Indoor Unit

Outdoor Unit

Heat Pump

/ Elec. Heat

System Model

      Indoor Unit

Outdoor Unit

Wall Mount Mini Split - Quad Zone

WMMS-4X09K-31B

WMMS-4X12K-31B

WMMS32X0912K-31B

WMMS-3X-1209K-31B

WMMS-2X(0912)K-31B

WMMS-09E(F)-31B

WMMS-12E(F)-31B

WMMS-09/12E(F)-31B

WMMS-12/09E(F)-31B

WMMS-09/12E(F)-31B

WMMS-4X09C-31B

WMMS-4X12C-31B

WMMS-3X0912C-31B

WMMS-3X1209C-31B

WMMS-2X(0912)C-31B

WMMS-4X09K-32B

WMMS-4X12K-32B

WMMS-3X0912K-32B

WMMS-3X1209K-32B

WMMS-2X(0912)K-32B

WMMS-09E(F)-32B

WMMS-12E(F)-32B

WMMS-09/12E(F)-32B

WMMS-12/09E(F)-32B

WMMS-09/12E(F)-32B

WMMS-4X09C-32B

WMMS-4X12C-32B

WMMS-3X0912C-32B

WMMS-3X1209C-32B

WMMS-2X(0912)C-32B

WMMS-4X09K-34B

WMMS-4X12K-34B

WMMS-3X0912K-34B

WMMS-3X1209K-34B

WMMS-2X(0912)K-34B

WMMS-09E(F)-34B

WMMS-12(E)F-34B

WMMS-09/12E(F)-34B

WMMS-12/09E(F)-34B

WMMS-09/12E(F)-34B

WMMS-4X09C-32B

WMMS-4X12C-32B

WMMS-3X0912C-32B

WMMS-3X1209C-32B

WMMS-2X(0912)C-34B

Wall Mount Mini -Basic Split 
Systems-Single & Multiple Zones

13 SEER

R410A 

IMPORTANT NOTES-About System Performance:

1) The rated performance data is tested under one of the  indoor & outdoor conditions at standard set-up installation.
2) Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting  pipe length/bending, elevation 
    difference between indoor and outdoor units, refrigerant level, vacuum level, leakage,  air or moisture or other contamilation level, foreign 
    substance left in the piping, indoor filter cleaness, indoor  and outdoor coil conditions, and others.
3) The electrical driving voltage and frequency, as well as the mechanical performing pressures and temperatures,  at different operating points, 
    during different operating periods, at different operating conditions. Suggest to measure temepratures and  pressures several minutes after 
    starting, when unit is stablized.
4) May refer to other specification tables or engineering  submittals, for detailed system performance at different conditions.
5) System performance will be degraded, if systems are improperly  selected, operated, installed, maintained, or serviced (which are not 
    conducted by manufacturer).

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Содержание M2 SERIES

Страница 1: ...his product is designed and manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional pra...

Страница 2: ...y parts may be new or refurbished All parts are tested and approved before shipping At no time does the YMGI Group warrant labor cost of any type Warranty will start from the date of successful instal...

Страница 3: ...nit for condensate leakage and refrigerant leakage before and after connecting them 28 Do you list the working details in the invoice and leave a copy to the customer 19 Did you charge the inter conne...

Страница 4: ...roperly can be more expensive than spending the little extra money that hiring the right contractor will cost Protect your investment and warranty eligibility by doing it right the first time THE FOLL...

Страница 5: ...e ability to claim freight damage is lost and YMGI will not replace the unit on this basis Contact the distributor or YMGI report the damage by forwarding the marked delivery receipt copy and pictures...

Страница 6: ...Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been completed and sent bac...

Страница 7: ...ed to keep from cold air blowing into propeller fan blade against airflow and so help unit work better in both AC cooling and HP heating mode in colder weather ranges IMPORTANT NOTES FOR UNIT OPERATIO...

Страница 8: ...n the ground Once stacking or bracket kit is used some outdoor units can be stacked 2 or 3 units high upon unit size and applications Air is discharged horizontally quietly and smoothly These units ar...

Страница 9: ...X24K 32B WMMS 2X30K 32B WMMS 09E F 32B WMMS 09 12E F 32B WMMS 12E F 32B WMMS 18E F 32B WMMS 24E F 32B WMMS 30E F 32B WMMS 2X09C 32B WMMS 0912C 32B WMMS 2X12C 32B WMMS 2X18C 32B WMMS 2X24C 32B WMMS 2X3...

Страница 10: ...4K 2 30K 3 09K 2 12 18K 3 12K 2 18 24K 2 09 12K 2 09 12 K 2 12 24K 3 12 24K Varies Varies Varies UNIT ENGINEERING SUBMITTALS MECHANIAL 09K 12K W H D 30 9 36 2 10 6 10 6 7 8 7 9 18K 24 36K 40 2 12 4 9...

Страница 11: ...thly without any abnormal noise or restriction 4 Fan wheel roration at outdoor unit should rotate freely and smoothly without any abnormal noise or restriction 5 No kinking or other leaking potentials...

Страница 12: ...ctricians only following NEC codes and manufacturer instructions CONNECTION OF WIRES SINGLE ZONE WIRING AT INDOOR UNIT AND OUTDOOR UNITS Open the front cover panel Remove screws from electrical box co...

Страница 13: ...taken into consideration when the connections of power cable are made such as the ambient temperature direct exposure to heat dirext exposure to sunlight The specifications for the power cable refer...

Страница 14: ...CLEARANCE REQUIRED AROUND UNITS SINGLE ZONE CLEARANCE REQUIRED AROUND UNITS DUAL ZONE Indoor unit B Indoor unit A SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainabl...

Страница 15: ...ndoor unit C SYSTEM LAYOUT INSTALLATION CLEARANCE Indoor unit A Indoor unit B Indoor unit C Indoor unit D SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainable and Ef...

Страница 16: ...screws Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate STEPS TO MOUNT PLATE a b c Drill mounting holes to make sure a...

Страница 17: ...rear side of plastic casing Snap the plastic casing bottom into the mounting plate gently Sealed with putty Secure the piping wiring set with clamp Trim the extra portion 2 in or less from floor 18 18...

Страница 18: ...35 45 CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS Firstly connect copper tubes at indoor unit Bend pipes by tools but not by hands Extra length is needed for future service REFRIGERANT...

Страница 19: ...ipes Over length soft pipes will lead to irregular bending Undersize bending will damage the soft pipe Short soft pipes will have them bending undersize it s not allowed INLTS STRT COUP COUP H OFST EL...

Страница 20: ...ks 1 Blink lit for 0 5 sec then off for 0 5 sec then lit for 0 5 sec 2 E4 Code Outdoor ambient temperature is too low do not to run unit during severe cold weather Refrigerant at low level users need...

Страница 21: ...hnician to make appointment with YMGI tech support and call us while the techician is at job site 4 Better to check the unit get problems and model model and serial ready before calling YMGI tech supp...

Страница 22: ...STALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS IMPORTANT NOTES FOR INSTALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS YMGI Engineered Comfort Products for A Sustainable and Efficient...

Страница 23: ...original licensed installer or current service contractor should be contacted first of all since they installed the unit and or know more details than anybody else They will check the unit and find o...

Отзывы: