2) For Products WMMS-M2 Series, made before 05/2010, Power L1/N1/G and L11/L22/G
don’t change, but control wires are 1/2 for AC, 1/2/3/4 for HP.
CONNECTION OF WIRES-SINGLE ZONE
Front (surface)
Panel
Wiring Cover
L1
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
AC-09/12K Models (115/1/60)
L1 N1
G
1
2
N1
G
1
2
AC-09/12/18/24/36K Models (208~230/1/60)
Front (surface)
Panel
Wiring Cover
L11
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
L11 L22 G
1
2
L22
G
1
2
Circuit Breaker/Discounect Switch
Circuit Breaker/Discounect Switch
Front (surface)
Panel
Wiring Cover
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
HP-09/12K Models (115/1/60)
L1 N1 G
1
2
3
HP-09/12/18/24/36K Models (208~230/1/60)
L1
N1
G
1
2
3
Circuit Breaker/Discounect Switch
4
4
Front (surface)
Panel
Wiring Cover
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
L11L22 G
1
2
3
L11 L22
G
1
2
3
Circuit Breaker/Discounect Switch
4
4
Notes:
o
1) Use UL-approved, minimum 90 C insulation, multi-stranded wires of enough AWG sizes (per MCA numbers,
not total current numbers) good for outdoor applications.
2) Follow NEC codes for wire sizes (MCA, length, environment, temperatures, and so on).
3) Wire tightly at all connections. Secure wires to keep from any potential damages (nailing, pressing, piercing...)
4) Must be wired by licensed electricians only, following NEC codes and manufacturer instructions.
CONNECTION OF WIRES-SINGLE ZONE
WIRING AT INDOOR UNIT AND OUTDOOR UNITS
* Open the front cover panel.
* Remove screws from electrical box cover and put screws in secured position.
* Remove screws from fastener and put screws in secured position.
* Prepare wires of right size and grade.
* Recommend to use factory-provided wire/cables.
* Connected to the terminals following wiring diagrams (terminal or color matches).
* Clamp power/control wires to the structure to keep the tension form being transmitted to the wire connection.
* Replace screws or fasteners back to where they were.
Front (surface)
Panel
Wiring Cover
L1
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
AC-09/12K Models (115/1/60)
L1 N1
G
1
3
N1
G
1
3
AC-09/12/18/24/36K Models (208~230/1/60)
Front (surface)
Panel
Wiring Cover
L11
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
L11 L22 G
1
3
L22
G
1
3
Circuit Breaker/Discounect Switch
Circuit Breaker/Discounect Switch
Front (surface)
Panel
Wiring Cover
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
HP-09/12K Models (115/1/60)
L1 N1 G
1
3
4
HP-09/12/18/24/36K Models (208~230/1/60)
L1
N1
G
1
3
4
Front (surface)
Panel
Wiring Cover
Indoor Unit
Outdoor Unit
Teminal block
of indoor unit
(To outdoor
unit)
Terminal match
L11 L22 G
1
3
4
L11 L22
G
1
3
4
Circuit Breaker/Discounect Switch
Circuit Breaker/Discounect Switch
1) For Products WMMS-M2 Series made after 05/2010