YMGI M2 SERIES Скачать руководство пользователя страница 2

All Units Shall Be Installed by Experienced or Licensed Contractor Or 

Technician. Read Manuals before Installation.

YMGI Group Will NOT Take Any Responsibilities for Any Damage or 

Loss Due to Do-It-Yourself(DIY) self-installation and other Improper Installation or Operation or 
Natural Disaster.

Connect All Wiring Securely. Loose Wire or Other Bad Contact May Cause 

Arc or Overheating and Fire Hazard.

Following NEC, State and Local Codes and Installation Instructions of All 

Units, Otherwise Unit Warranty Will Be Void and Serious Damage To People Or Property May Be 
Caused.

Don't Supply Power until All Wiring and Tubing and Checking is 

Completed. Ground the Unit Following Instructions and NEC, State and Local Codes.

Installation or Service Technician to Contact Manufacturer Technical Support

Toll Free Number: 1-866-833-3138 x 703

Email: [email protected]

(For any abnormal or unit issues, end user needs to contact installation or service contractor 

to check the unit, before having them contact manufacturer technical support for technical 

diagnosis or trouble shooting help.)

MUST READ

CONTENTS

P1 OF 44

P2 OF 44

33
34

23

23

21

29
29

35
36

32

37

39
40
41

2

43
44

25

17

13

16

12

14

3

24
24

BEFORE INSTALLATION IDENTIFY COMPONENTS

CONNECTION OF WIRES-SINGLE ZONE

MINI WALL MOUNT SYSTEMS-MODELS

CONNECTION OF PIPES AND WIRES
GET READY FOR INSTALLATION

IMPORTANT NOTES FOR UNIT OPERATION ABMIENT & SIZING
BRIEF INTRODUCTION TO MINI SPLIT WALL MOUNT SYSTEM

IMPORTANT NOTES

UNIT ENGINEERING SUBMITTALS-MECHANIAL

ENGINEERING SUBMITTAL-UNIT SIZES & WEIGHT

SYSTEM LAYOUT & INSTALLATION CLEARANCE

INSTALLATION LOCATIONS & CAUTIONS
INSTALLATION POSITIONS FOR OUTDOOR UNIT

HEIGHT LIMITS OF INDOOR AND OUTDOOR UNITS
INSTALLATION-INDOOR UNIT
INSTALLATION-OUTDOOR UNIT
WIRING OUTDOOR UNIT
CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS
PIPING GUIDE
INSTALLATION OF ACCESSORIES
VACUUM AND LEAKAGE CHECK

CHECK AFTER INSTALLATION AND TEST OPERATION

IMPORTANT NOTES FOR INSTALLATION OF MULTIPLE ZONE SYSTEMS (MULTIPLE COMPRESSORS)

LIMITED PRODUCT WARRANTY POLICIES
LIMITED PRODUCT WARRANTY REGISTRATION CARD

WARRANTY AND TECH. SUPPORT
USER NOTES AND SERVICE LOG

11

15

19
19
20

IMPORTANT NOTES FOR UNIT OPERATION ABMIENT & SIZING
MANUFACTURE'S IMPORTANT NOTES FOR INSTALLING CONTRACTOR/TECHNICIAN

RECOMMENDED TOOLS FOR INSTALLATION

37
38

SYSTEM INSPECTION AND TRIAL RUNNING
LED DISPLAY PANEL

DIAGNOSIS CODE & TROUBLE-SHOOTING GUIDELINE

LIMITED PRODUCT WARRANTY POLICIES

The YMGI products are designed and manufactured free from defects in workmanship, and materials for normal 
use. However, for any reason, including many handlings and occasions between the YMGI factories/warehouses 
and where you receive the products, the unit doesn't work, YMGI Group will help to remedy the occurrence in the 
following warranting ways:  

Compressor: 

YMGI will warrant the compressor of YMGI-validated and approved warranty filing, for a period of 

5 years from the date of successful installation at original location.

Parts: 

YMGI will warrant parts of YMGI-validated and approved warranty filing, for one year from the date of 

successful installation at original location.  

All warranty compressors and parts replaced will become the sole property of YMGI Group and must be returned 
to YMGI Group upon request.  Warranty parts may be new or refurbished. All parts are tested and approved 
before shipping.

At no time does the YMGI Group warrant labor cost of any type. Warranty will start from the date of 
successful installation at initial location, or 90 days as of original shipping date from YMGI Group, 
whichever comes first.

This is a standard warranty of limited liability and DOES NOT cover the following:

* Any damage or repairs to properties, or persons as an incident or consequence of improper or faulty 
  transportation, installation, operation, maintenance or service.
* Damage caused by frozen or broken water hoses or refrigeration pipes in the event of equipment failure.
* Any damage as a result of floods, fire, wind, lightening, accidents, corrosive atmosphere or any other conditions 
  beyond the control of YMGI Group.
* Any damage due to interruption or inadequate electrical service to equipment.
* Any products that are installed outside the US or Canada.
* Any unit that has been moved from the original installation address.
* Any labor costs associated with the installation or service of the unit.
* Poor unit performance due to improper unit selection (SEER, Unit size).

To validate the above warranties, ALL the following conditions must all be fulfilled:

1. The unit was fully (100%) and successfully installed by licensed or certified HVAC technicians.
2. The unit was installed following all NEC, state and local codes.
3. The unit was installed following all instructions and manuals made by YMGI Group.
4. ALL fields, especially the technician-checklist, of the 

Limited Warranty Registration Card/Form

 were filled 

    completely by the installing technician and signed by both the installing company technician and the unit owner.
5. The 

Limited Warranty Registration Card/Form

 and a copy of the original installing company's invoice had 

    been received by YMGI Group-Warranty Dept., POB 1559, O'Fallon, MO 63366, within 7 days of successful 
    installation.

No warranty filing will be validated or approved, if any one of the above 5 conditions is not met.
Product registration doesn't guarantee the validity of this limited warranty statement.

Steps to follow for warranty part replacement:

1. Installing or service technician contacts YMGI tech support at 1-866-833-3138 ext 703 from the jobsite, to 
    double-check and confirm with YMGI Technical support the exact part(s) needed to fix all the problems.
2. YMGI will check the customer's warranty filing. Parts for validated and approved warranty will not be charged. 
    Parts of invalid warranty filing or unapproved warranty requesting, will be charged accordingly.
3. YMGI will ground ship out the parts ASAP. Expedited shipping is available at the customer's cost.
4. Replacement parts of approved warranty registration are to be warranted for the remainder of the 1 year parts 
    and 5 year compressor warranty. Purchasing of replacement parts of invalid warranty filing or unapproved 
    warranty requesting, will be as they are and bear no warranty.

YMGI keeps on improving products with various engineering changes without prior notice.  Such improvements 
or changes include but not limited to product specification, appearance, functions, sizes, packaging and others.  
These improvements or changes will not void the limited warranty stated herein. YMGI keeps the final explanation 
of this warranty policy.

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

CUSTOMER AND TECHNICIAN MUST READ

4

Содержание M2 SERIES

Страница 1: ...his product is designed and manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional pra...

Страница 2: ...y parts may be new or refurbished All parts are tested and approved before shipping At no time does the YMGI Group warrant labor cost of any type Warranty will start from the date of successful instal...

Страница 3: ...nit for condensate leakage and refrigerant leakage before and after connecting them 28 Do you list the working details in the invoice and leave a copy to the customer 19 Did you charge the inter conne...

Страница 4: ...roperly can be more expensive than spending the little extra money that hiring the right contractor will cost Protect your investment and warranty eligibility by doing it right the first time THE FOLL...

Страница 5: ...e ability to claim freight damage is lost and YMGI will not replace the unit on this basis Contact the distributor or YMGI report the damage by forwarding the marked delivery receipt copy and pictures...

Страница 6: ...Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been completed and sent bac...

Страница 7: ...ed to keep from cold air blowing into propeller fan blade against airflow and so help unit work better in both AC cooling and HP heating mode in colder weather ranges IMPORTANT NOTES FOR UNIT OPERATIO...

Страница 8: ...n the ground Once stacking or bracket kit is used some outdoor units can be stacked 2 or 3 units high upon unit size and applications Air is discharged horizontally quietly and smoothly These units ar...

Страница 9: ...X24K 32B WMMS 2X30K 32B WMMS 09E F 32B WMMS 09 12E F 32B WMMS 12E F 32B WMMS 18E F 32B WMMS 24E F 32B WMMS 30E F 32B WMMS 2X09C 32B WMMS 0912C 32B WMMS 2X12C 32B WMMS 2X18C 32B WMMS 2X24C 32B WMMS 2X3...

Страница 10: ...4K 2 30K 3 09K 2 12 18K 3 12K 2 18 24K 2 09 12K 2 09 12 K 2 12 24K 3 12 24K Varies Varies Varies UNIT ENGINEERING SUBMITTALS MECHANIAL 09K 12K W H D 30 9 36 2 10 6 10 6 7 8 7 9 18K 24 36K 40 2 12 4 9...

Страница 11: ...thly without any abnormal noise or restriction 4 Fan wheel roration at outdoor unit should rotate freely and smoothly without any abnormal noise or restriction 5 No kinking or other leaking potentials...

Страница 12: ...ctricians only following NEC codes and manufacturer instructions CONNECTION OF WIRES SINGLE ZONE WIRING AT INDOOR UNIT AND OUTDOOR UNITS Open the front cover panel Remove screws from electrical box co...

Страница 13: ...taken into consideration when the connections of power cable are made such as the ambient temperature direct exposure to heat dirext exposure to sunlight The specifications for the power cable refer...

Страница 14: ...CLEARANCE REQUIRED AROUND UNITS SINGLE ZONE CLEARANCE REQUIRED AROUND UNITS DUAL ZONE Indoor unit B Indoor unit A SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainabl...

Страница 15: ...ndoor unit C SYSTEM LAYOUT INSTALLATION CLEARANCE Indoor unit A Indoor unit B Indoor unit C Indoor unit D SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainable and Ef...

Страница 16: ...screws Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate STEPS TO MOUNT PLATE a b c Drill mounting holes to make sure a...

Страница 17: ...rear side of plastic casing Snap the plastic casing bottom into the mounting plate gently Sealed with putty Secure the piping wiring set with clamp Trim the extra portion 2 in or less from floor 18 18...

Страница 18: ...35 45 CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS Firstly connect copper tubes at indoor unit Bend pipes by tools but not by hands Extra length is needed for future service REFRIGERANT...

Страница 19: ...ipes Over length soft pipes will lead to irregular bending Undersize bending will damage the soft pipe Short soft pipes will have them bending undersize it s not allowed INLTS STRT COUP COUP H OFST EL...

Страница 20: ...ks 1 Blink lit for 0 5 sec then off for 0 5 sec then lit for 0 5 sec 2 E4 Code Outdoor ambient temperature is too low do not to run unit during severe cold weather Refrigerant at low level users need...

Страница 21: ...hnician to make appointment with YMGI tech support and call us while the techician is at job site 4 Better to check the unit get problems and model model and serial ready before calling YMGI tech supp...

Страница 22: ...STALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS IMPORTANT NOTES FOR INSTALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS YMGI Engineered Comfort Products for A Sustainable and Efficient...

Страница 23: ...original licensed installer or current service contractor should be contacted first of all since they installed the unit and or know more details than anybody else They will check the unit and find o...

Отзывы: