Find the cooling/heating load capacity of the space where the unit will be in service. Select matched WMMS 
units for the space. Under sizing or over sizing equipment is NOT recommended.

Mini Split Wall Mount Systems come with three types: cooling only and heat pump and heat pump with electric 
heater. These units can be easily wired. Either indoor unit or outdoor unit can be used with any matched 
comparable outdoor unit or indoor unit as long as they have matched size and control. Must refer to electrician 
before doing so. 

Each system is fully tested per rigorous standards at factory. Acoustically and thermally balanced design and 
systematically optimized system give each unit a healthy birth off the assembly line with proved quality and 
reliability.

Since outdoor units can be installed on the wall or balcony, where is close to indoor unit, at least the following 
benefits will be brought to contractors and customers: 

* Indoor unit operates much quieter than air diffuser of central air conditioning system.
* Stylish design of indoor unit adds beauty to rooms.
* Connection pipe, refrigerant usage is much saved compared to installing up-flow condensing units on the 
   ground and long copper/wire lines needed between indoor and outdoor units.
* Contractor work is eased and time is saved.
* Efficiency and lifetime of system is increased.

IMPORTANT NOTES: 

1) Working temperature ranges listed above are designed for units to work properly, though these temperature 
     ranges are conservative.

2) Units may still work well out of the guaranteed working temperature ranges, as long as they are installed 
    properly and are still in good conditions within design envelope.

3) Units are designed for mild low temperature AC cooling applications. Units come with low temperature control 

o

    to protect agent too low pressure when running for AC cooling in weather colder than 45 F and warmer than 

o

    35 F. In this temperature ranges, units may not need to add refrigerant and/or jumper at low pressure switch. 

o

    If units are to be used for cooling only below 35 F, then better to check and add refrigerant and jumper at low 
    pressure switch. Situation varies upon indoor load and indoor unit installation conditions such as TEX type, 
    elevation vs outdoor unit, copper line set size and length, refrigerant level and leakage level.

o

4) Units may still work HP heating well way below 17 F, though exact temperatures are not listed. Units will 
    defrost during HP heating model in cold weather. Suction (bigger) pipe should be hot and the discharge 
    (smaller) pipe should be warm at outdoor unit during HP heating mode, if everything is right. 

6) Optional component Wind Baffle installed at fan discharge side on the cabinet is designed to keep from cold 
    air blowing into propeller fan blade against airflow, and so help unit work better in both AC cooling and HP 
    heating mode in colder weather ranges.

IMPORTANT NOTES FOR UNIT OPERATION ABMIENT & SIZING

Too Cold

Not Cold

Too Hot

Not Hot

5) In low temperature ranges, it is always reeommended to add one low ambient comtroller to the outdoor unit. 
    Recommended model is ICM 326HN. Following the low ambient control manufacturer for proper wiring and 
    set-up.

IMPORTANT NOTES

These precautions are essential and must be strictly observed.

DO NOT

 pull on the power cord or refrigeration lines. 

Install them in a secured position. A line set plastic 
cover is recommended.

DO NOT

 install the unit in places where there is 

exposure to flammable materials or gas leakage. 

DO NOT

 use wire or circuit breakers that do not meet 

electrical safety standards.  Several circuits cannot 
be connected to one breaker.

DO NOT

 wire or open the unit while it is running. 

Make sure to shut off all circuits prior to inspecting or 
servicing the unit.

DO NOT

 install unit in a damp laundry room or near 

flammable gas. All units must be protected by 
certified electrical circuit breakers and in accordance 
with all safety codes.

DO NOT

 use the unit in cool or dry mode for 

prolonged periods where humidity is higher than 80%. 

SAFETY WARNINGS

READ THESE SAFETY WARNINGS COMPLETELY PRIOR TO ANY USE. 

DO NOT

 install the indoor unit close to cooking 

surfaces or ventilation systems. Poor placement 
could inhibit peak performance.       

DO NOT

 blow cold air directly towards people for 

extended periods. It may get you a bad cold.  

DO NOT

 use chemical solvents, flammable 

insecticides, or abrasive materials. Clean the unit 
only with a soft dry cloth or rag.

DO NOT

 continue to operate the unit if there is any 

abnormal odor, burning, scorching, or smoke. Stop 
and disconnect the unit immediately.

DO NOT

 use the system for anything other than what 

it was designed for or any non-HVAC purposes. Do 
not store near food, paint, or other chemicals.

DO NOT

 operate the unit for prolonged periods 

without refreshing ambient air. Opening a door or 
window periodically will suffice.

DO NOT

 draw on the power cord or refrigeration

lines. Install them in secured positions. Plastic
cover of line set is recommended.

DO NOT

 blow the cold air directly towards people

for prolonged period. Otherwise, people may get
cold.

DO NOT

 use smaller than enough wires. Do not

put several circuits to one breaker. Don't use
smaller than enough circuit breakers. Otherwise
power failure or fire may be caused.                

DO NOT

 wire or open unit while unit is running.

Sparks or fire may occur. It may cause a shock to
people. 

Ground connection

Forbidden

Disconnect the plug

Imperative

 

MUST READ

MUST READ

P11 OF 36

P12 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Содержание M2 SERIES

Страница 1: ...his product is designed and manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional pra...

Страница 2: ...y parts may be new or refurbished All parts are tested and approved before shipping At no time does the YMGI Group warrant labor cost of any type Warranty will start from the date of successful instal...

Страница 3: ...nit for condensate leakage and refrigerant leakage before and after connecting them 28 Do you list the working details in the invoice and leave a copy to the customer 19 Did you charge the inter conne...

Страница 4: ...roperly can be more expensive than spending the little extra money that hiring the right contractor will cost Protect your investment and warranty eligibility by doing it right the first time THE FOLL...

Страница 5: ...e ability to claim freight damage is lost and YMGI will not replace the unit on this basis Contact the distributor or YMGI report the damage by forwarding the marked delivery receipt copy and pictures...

Страница 6: ...Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been completed and sent bac...

Страница 7: ...ed to keep from cold air blowing into propeller fan blade against airflow and so help unit work better in both AC cooling and HP heating mode in colder weather ranges IMPORTANT NOTES FOR UNIT OPERATIO...

Страница 8: ...n the ground Once stacking or bracket kit is used some outdoor units can be stacked 2 or 3 units high upon unit size and applications Air is discharged horizontally quietly and smoothly These units ar...

Страница 9: ...X24K 32B WMMS 2X30K 32B WMMS 09E F 32B WMMS 09 12E F 32B WMMS 12E F 32B WMMS 18E F 32B WMMS 24E F 32B WMMS 30E F 32B WMMS 2X09C 32B WMMS 0912C 32B WMMS 2X12C 32B WMMS 2X18C 32B WMMS 2X24C 32B WMMS 2X3...

Страница 10: ...4K 2 30K 3 09K 2 12 18K 3 12K 2 18 24K 2 09 12K 2 09 12 K 2 12 24K 3 12 24K Varies Varies Varies UNIT ENGINEERING SUBMITTALS MECHANIAL 09K 12K W H D 30 9 36 2 10 6 10 6 7 8 7 9 18K 24 36K 40 2 12 4 9...

Страница 11: ...thly without any abnormal noise or restriction 4 Fan wheel roration at outdoor unit should rotate freely and smoothly without any abnormal noise or restriction 5 No kinking or other leaking potentials...

Страница 12: ...ctricians only following NEC codes and manufacturer instructions CONNECTION OF WIRES SINGLE ZONE WIRING AT INDOOR UNIT AND OUTDOOR UNITS Open the front cover panel Remove screws from electrical box co...

Страница 13: ...taken into consideration when the connections of power cable are made such as the ambient temperature direct exposure to heat dirext exposure to sunlight The specifications for the power cable refer...

Страница 14: ...CLEARANCE REQUIRED AROUND UNITS SINGLE ZONE CLEARANCE REQUIRED AROUND UNITS DUAL ZONE Indoor unit B Indoor unit A SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainabl...

Страница 15: ...ndoor unit C SYSTEM LAYOUT INSTALLATION CLEARANCE Indoor unit A Indoor unit B Indoor unit C Indoor unit D SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainable and Ef...

Страница 16: ...screws Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate STEPS TO MOUNT PLATE a b c Drill mounting holes to make sure a...

Страница 17: ...rear side of plastic casing Snap the plastic casing bottom into the mounting plate gently Sealed with putty Secure the piping wiring set with clamp Trim the extra portion 2 in or less from floor 18 18...

Страница 18: ...35 45 CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS Firstly connect copper tubes at indoor unit Bend pipes by tools but not by hands Extra length is needed for future service REFRIGERANT...

Страница 19: ...ipes Over length soft pipes will lead to irregular bending Undersize bending will damage the soft pipe Short soft pipes will have them bending undersize it s not allowed INLTS STRT COUP COUP H OFST EL...

Страница 20: ...ks 1 Blink lit for 0 5 sec then off for 0 5 sec then lit for 0 5 sec 2 E4 Code Outdoor ambient temperature is too low do not to run unit during severe cold weather Refrigerant at low level users need...

Страница 21: ...hnician to make appointment with YMGI tech support and call us while the techician is at job site 4 Better to check the unit get problems and model model and serial ready before calling YMGI tech supp...

Страница 22: ...STALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS IMPORTANT NOTES FOR INSTALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS YMGI Engineered Comfort Products for A Sustainable and Efficient...

Страница 23: ...original licensed installer or current service contractor should be contacted first of all since they installed the unit and or know more details than anybody else They will check the unit and find o...

Отзывы: