YMGI M2 SERIES Скачать руководство пользователя страница 6

F. Charges for your return:
1)A restocking charge of 25% creditable invoice value.
2)All return shipping fees.
3)Additional fees will be charged, if products are found to be damaged, missing or used.
4)YMGI will notify the distributor of the charges only after the inspection and assessment of the returned products 
    has been completed.

Attention:

1) Returned products must be shipped within 7 days of YMGI's releasing of 

RGA #

.

2) 

All RGA

 shipping shall be prepaid by the customer. 

YMGI will not accept any COD freight

.

YMGI GROUP DISCLAIMING-1: 

YMGI Group will NOT accept any return, or may not honor 100% credit for any return of Product(s)/Part(s)/
Accessories, in any of the following cases:
* Return requests made 30 or more days after the date of original sales shipping from YMGI Group warehouse.
* Return shipment is initiated 8 days or more after the RGA is approved.
* Returned products received not displaying an YMGI-approved valid 

RGA #

.

* Returned products received C.O.D.
* Returned products not received in the original packaging.
* Returned products received with non-repairable packaging, including duct tape or marks on units or carton 
  boxes.
* Returned products received with missing units/parts/accessories.
* Returned products received, are found to be non-functional or damaged.

YMGI GROUP DISCLAIMING-2: 

YMGI Group will not be responsible for any losses of returned unit(s)/part(s)/accessories in transition to YMGI 

  Group warehouse. 
* YMGI Group RGA is valid for seven (7) days from the original issuing date. Returns will not be accepted, if 
  shipping is made 8 or more days after the YMGI Group RGA is issued.

DEFECTIVE UNITS / PARTS / ACCESSORIES-REPAIR OR REPLACEMENT

Out of thousands of units sold every year, there may be an occasional instance your product does not operate 
properly. Reasons of but are not limited to: 

manufacturing, installation, operation, maintenance and 

knowledge of operator

The defects might be found before/ during installation or in the operation of the unit. Defects can be in the form 
of blown fuse(s), defective control board(s), damaged remote control, loose or missing screws, etc. These 
defective parts can be replaced easily.

Some functions of our units are different from what are typical in traditional split type air conditioning and heat 
pump systems and similar systems made by other manufacturers. These are not defects. Take some time to 
learn the functions of your unit. We will be happy to assist you with any questions you may have concerning the 
functions of your new unit.

1. 

Part repair or replacement after trouble-shooting: 

 This is the most common and generally the easiest and 

    most economical way for all parties, since the problem and all part needs can be accurately and completely     
    identified. 

* Your technician calls our technical support line, from your job site, after checking your units and getting all the information 
  ready.
* Our technical support will go through several steps, over the phone or through email, with your technician, in order to help 
  identify and resolve the problems. Normally wiring correction, piping correction, part repair/ replacement will resolve the 
  problems. 

* Your technician will then need to verify and confirm the problem(s) before YMGI can ship out the replacement part(s). 
  Inaccurate or incomplete troubleshooting or part replacement will delay the repair. YMGI technical support will only speak 
  with a licensed/certified technician in regards to the repair of your unit.  In our experience this saves time and money for 
  all parties involved.

Your technician is the only person to perform any physical checking, trouble-shooting and replacing of any 
defective part(s) for your units. Our factory technical support is just a help.  

YMGI provided no labor warranty 

on the products.

 

2. Unit/part repair at our workshop(s):

  Due to the limitations of our technical support not being at your job site, 

    or your technician's experience with our product, the problem may not be resolved as quickly as would be 
    desired.

 

If the problem is still not resolved after attempts between your technician and our technical support, 

    you can elect to have the unit repaired at our facility.  If this step is chosen:

1) YMGI will send to you the 

Customer Request to Ship Products to YMGI Service Center for Inspection and Repair, 

    and Authorization to Charge 

form.

2) You will review the form and fill all fields appropriately, sign and send back to the YMGI Group.
3) Once the form has been completed and sent back to YMGI, remove the units and ship back to YMGI.

Please make a note describing the problem and communication history, if possible. Our technicians will check the 
units and find the problem(s), repair the issue(s), and ship the unit back to you following the conditions set forth in 
the signed repair agreement. All unit removal and re-installation is done at your cost

 

and must be done by a 

currently valid licensed HVAC technician.

3. Unit replacement:

 Only applies to those defects reported within 30 days of original purchase date

 

and if all 

    necessary warranty paperwork had been received and approved. This option applies only if the above steps 
    cannot resolve the problem(s). Either indoor or outdoor unit replacement is available, based on the actual need, 
    at YMGI's determination. 

This option shall be the last resort

, due to refrigerant and wiring considerations. All 

    unit removal, re-installation and shipping cost are the responsibility of the customer.

 

YMGI maintains the final 

    authority as to unit replacement.  Replacement will be made with the same model only.  Alternate units will be 
    treated as a new order. 

Returning Replaced Defective Units/Parts/Accessories After Unit Repair: (

Only applies to steps 1&3 above)

1) Repack the replaced unit/ part /accessory in the box which contained the replacement part. 
2) Parts can be boxed for UPS, FedEx or equivalent ground service. Units shall be secured onto the skid on which the 
    replacement was shipped after placing into the

 

package from the replacement

 

product.

3) Ship 

all

 replaced products, to YMGI-designated location. You will be charged if YMGI does not receive the replaced parts.

Standard factory warranty does not cover the cost of materials and labor that are incurred at your site. 
There will be no cost for the replacement unit, if YMGI determines the defect is manufacturer related. 
Replacement will be made with the same model,

 

only.  Alternate units will be treated as a new order.

CUSTOMER SERVICE / TECHNICAL SUPPORT FROM YMGI GROUP

For questions or help with your unit, contact the original installer or service provider.
YMGI Group does not install nor physically service your unit. Your installer or service provider must check the 
unit prior to contacting YMGI Group from your jobsite, in order to be helped in an efficient and timely manner.
* Factory customer service at [email protected] Tel: 1-866-833-3138x704
* Factory technical support at [email protected] Tel: 866-833-3138x703
* Fax: 1-866-377-3355
An 

"YMGI Group Customer Service/Technical Support Daily Log Sheet"

 will be filed in writing at our office, 

for effective communication between you and YMGI Group customer service, your technician and YMGI Group 
technical support. Before contacting the YMGI Group locate the IP# written at the top of your warranty registration 
form.  Use this IP# whenever you contact the YMGI Group.

Equipment failure does not automatically denote a product defect from the factory assembly line. The defects can 
be caused, during production, transportation, installation, operation, maintenance, or service. Defects may NOT 
be the responsibility of the manufacturer. Nobody willfully or intentionally produces a defective product. No 
determination shall be made until the technical issue(s) or the causes of the defect(s) are identified.

If a defect is found, whether at the original installation, or during normal operation, we will gladly help you in the 
following steps in sequence from 1 to 3:

DISTRIBUTOR AND MANUFACTURER POLICIES

* All questions concerning sales or money will be directed to the sales distributor from which you purchased the 
  units.
* Read and follow all policies set forth from the distributor from which you purchased your unit.
* Upon purchase and installation of the unit(s), you agree to be bounded by all policies published by both 
  distributors and YMGI.
* MGI Group has the final authority and supersedes other related parties (distributors, etc.) concerning all policies 
  regarding YMGI products.

CUSTOMER AND TECHNICIAN MUST READ

CUSTOMER AND TECHNICIAN MUST READ

MUST READ

MUST READ

P9 OF 36

P10 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Содержание M2 SERIES

Страница 1: ...his product is designed and manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional pra...

Страница 2: ...y parts may be new or refurbished All parts are tested and approved before shipping At no time does the YMGI Group warrant labor cost of any type Warranty will start from the date of successful instal...

Страница 3: ...nit for condensate leakage and refrigerant leakage before and after connecting them 28 Do you list the working details in the invoice and leave a copy to the customer 19 Did you charge the inter conne...

Страница 4: ...roperly can be more expensive than spending the little extra money that hiring the right contractor will cost Protect your investment and warranty eligibility by doing it right the first time THE FOLL...

Страница 5: ...e ability to claim freight damage is lost and YMGI will not replace the unit on this basis Contact the distributor or YMGI report the damage by forwarding the marked delivery receipt copy and pictures...

Страница 6: ...Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been completed and sent bac...

Страница 7: ...ed to keep from cold air blowing into propeller fan blade against airflow and so help unit work better in both AC cooling and HP heating mode in colder weather ranges IMPORTANT NOTES FOR UNIT OPERATIO...

Страница 8: ...n the ground Once stacking or bracket kit is used some outdoor units can be stacked 2 or 3 units high upon unit size and applications Air is discharged horizontally quietly and smoothly These units ar...

Страница 9: ...X24K 32B WMMS 2X30K 32B WMMS 09E F 32B WMMS 09 12E F 32B WMMS 12E F 32B WMMS 18E F 32B WMMS 24E F 32B WMMS 30E F 32B WMMS 2X09C 32B WMMS 0912C 32B WMMS 2X12C 32B WMMS 2X18C 32B WMMS 2X24C 32B WMMS 2X3...

Страница 10: ...4K 2 30K 3 09K 2 12 18K 3 12K 2 18 24K 2 09 12K 2 09 12 K 2 12 24K 3 12 24K Varies Varies Varies UNIT ENGINEERING SUBMITTALS MECHANIAL 09K 12K W H D 30 9 36 2 10 6 10 6 7 8 7 9 18K 24 36K 40 2 12 4 9...

Страница 11: ...thly without any abnormal noise or restriction 4 Fan wheel roration at outdoor unit should rotate freely and smoothly without any abnormal noise or restriction 5 No kinking or other leaking potentials...

Страница 12: ...ctricians only following NEC codes and manufacturer instructions CONNECTION OF WIRES SINGLE ZONE WIRING AT INDOOR UNIT AND OUTDOOR UNITS Open the front cover panel Remove screws from electrical box co...

Страница 13: ...taken into consideration when the connections of power cable are made such as the ambient temperature direct exposure to heat dirext exposure to sunlight The specifications for the power cable refer...

Страница 14: ...CLEARANCE REQUIRED AROUND UNITS SINGLE ZONE CLEARANCE REQUIRED AROUND UNITS DUAL ZONE Indoor unit B Indoor unit A SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainabl...

Страница 15: ...ndoor unit C SYSTEM LAYOUT INSTALLATION CLEARANCE Indoor unit A Indoor unit B Indoor unit C Indoor unit D SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainable and Ef...

Страница 16: ...screws Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate STEPS TO MOUNT PLATE a b c Drill mounting holes to make sure a...

Страница 17: ...rear side of plastic casing Snap the plastic casing bottom into the mounting plate gently Sealed with putty Secure the piping wiring set with clamp Trim the extra portion 2 in or less from floor 18 18...

Страница 18: ...35 45 CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS Firstly connect copper tubes at indoor unit Bend pipes by tools but not by hands Extra length is needed for future service REFRIGERANT...

Страница 19: ...ipes Over length soft pipes will lead to irregular bending Undersize bending will damage the soft pipe Short soft pipes will have them bending undersize it s not allowed INLTS STRT COUP COUP H OFST EL...

Страница 20: ...ks 1 Blink lit for 0 5 sec then off for 0 5 sec then lit for 0 5 sec 2 E4 Code Outdoor ambient temperature is too low do not to run unit during severe cold weather Refrigerant at low level users need...

Страница 21: ...hnician to make appointment with YMGI tech support and call us while the techician is at job site 4 Better to check the unit get problems and model model and serial ready before calling YMGI tech supp...

Страница 22: ...STALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS IMPORTANT NOTES FOR INSTALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS YMGI Engineered Comfort Products for A Sustainable and Efficient...

Страница 23: ...original licensed installer or current service contractor should be contacted first of all since they installed the unit and or know more details than anybody else They will check the unit and find o...

Отзывы: