![Yeswelder YWM-200 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/yeswelder/ywm-200/ywm-200_operators-manual_4661489008.webp)
Standard Voltage /Frequency
220V±10% 50/60Hz
110V±10% 50/60Hz
Input Current
I
1 max
=34A, I
1 eff
=26.3A
I
1 max
=50A, I
1 eff
=38.7A
INPUT-SINGLE PHASE ONLY
RATED OUTPUT-DC ONLY
OUTPUT RANGE
OTHER PARAMETERS
PACKING DIMENSIONS
TEMPERATURE RANGE
Voltage
220V
110V
Mode
GMAW
SMAW
GTAW
GMAW
SMAW
GTAW
Duty Cycle
60%
100%
60%
100%
60%
100%
60%
100%
60%
100%
60%
100%
Current
200A
158A
180A
139A
200A
155A
160A
123A
145A
112A
160A
124A
Volts at Rated
Current
24V
21.9V
27.2V
25.5V
18V
16.2V
22V
20.1V
25.8V
24.5V
16.4V
15V
Voltage
220V
110V
Mode
GMAW
SMAW
GTAW
GMAW
SMAW
GTAW
Open Circuit
Voltage
62V
Welding
Current Range
30A~200A
20A~180A
10A~200A
30A~160A
20A~145A
10A~160A
Welding
Voltage Range
15.5V~24V
20.8V~27.2V
10.4V~18V
15.5V~22V
20.8V~25.8V
10.4V~16.4V
Machine Power Factor Efficiency
Protection Class Insulation Class
0.8
≥80%
IP21S
F
YWM-200
Machine
YWM-200
Length
Width
Height
Weight
540mm
360mm
445mm
17.65Kg
Operating Temperature Range
-20°C ~ +50°C(-4°F~122°F)
Storage Temperature Range
-20°C ~ +50°C(-4°F~122°F)
TECHNICAL SPECIFICATIONS: YWM-200
INSTALLATION
- 5 -
Read the entire installation section before you start
the installation.
INSTALLATION
WARNIG
ELECTRIC SHOCK can kill.
Ÿ
Only qualified personnel should per-
form this installation.
Ÿ
Only personnel reading and under-
standing the YWM-200 Operator’s Man-
ual should install and operate this
equipment.
Ÿ
The machine must be plugged into a grounded receptacle
per national, local, or other applicable electrical codes.
Ÿ
The YWM-200 power switch should be in the OFF(“O”) po-
sition when installing the work cable and gun and con-
necting the power cord to input power.
SELECT SUITABLE LOCATION
STACKING
Locate the YWM-200 in a dry place with free clean air circula-
tion to minimize the chance of dirt accumulation that can block
air passages and cause overheating.
YWM-200
cannot be stacked.
TILTING
The machine should be placed on a secure, level surface or a
recommended cart. The equipment may topple over if this re-
quirement is not followed.
Содержание YWM-200
Страница 34: ...31 WIRING DIAGRAM...
Страница 35: ......
Страница 36: ...WE ALWAYS STAND BEHIND IT Toll Free 855 937 4567 www yeswelder com...