Yatai Inverter YTB-S-LT User’s Manual
beginning time, and then PI control the velocity. For instance: if 1-04 is set up to 40.0 mm
,
1-02 is set up to
300m/min, then if 1 Hz is estimated according to 30 R/min, the target frequency for beginning operating is
300*1000
/
40.0
/
30
/
3.14
=
79.62Hz. When the target frequency setting up is above 150 Hz
,
for the
purpose of protecting the machine equipment, the converter still operates according to 150 Hz.
Setting Range
0: Yarn Length=Length Setting
1: Yarn Length=Length
Setting*10
1-05 Unit for Displaying the
Yarn Length
Factory Value: 0
2: Yarn Length=Length
Setting*100
In the mode of constant velocity, this parameter is used to select the display accuracy of the digital display
indicator, which is coordinately used with the function code of 0-05 to complete counting of the different
length. For instance: if 0-05 is set up as 1000 and 1-05 is set up as 0 then the length of the spinning yarn is
with the maximum value of 1000m and the display length is with the minimum value is 1 m; otherwise if
the 1-05 is set up as 1, then the length of the spinning yarn is with the maximum value of 10000m and the
display length is with the minimum value of 10m; else if the 1-05 is set up as 2 then the length of the
spinning yarn is with the maximum value of 100000m and the display length is with the minimum value of
100m. The users can set up them according to the actual situation.
Function 2 (Only the 0-06 is set up as no “1”, the parameters in this data district are valid.)
Setting Range: Lower Limit
Frequency
~
150.0Hz
2-00 Starting Frequency
Factory Value: 60.00
Setting Range: 10.00Hz
~
Upper
Limit Frequency
Factory Value: 40.00
2-01 Stopping Frequency
The Parameter 2-00 together with 2-01 can satisfy different spinning requirements.
When control with frequency decreasing progressively, the Starting Frequency refers to the target frequency
- 27 -