Yatai Inverter YTB-S-LT User’s Manual
3.3.2
Reference of the Loop Wiring
Table 3-4
Loop Wiring Reference Table
Power
Primary
Rating
Input
Circuit
Converter Model
Input Capacity
Current
Output
Output
Power
Current (A)
Wiring
(mm
2
)
Single Phase
220V
,
1KVA
5A 0.4KW 2.5
1.5
YTB-S-LT-0.4KW
Single Phase
220V
,
2KVA
9A 0.75KW 4.5
2.5
YTB-S-LT-0.75KW
♦
The longest distance of input and output lines ought to be within 300 meters in order to ensure the
electromagnetic compatibility requirements.
♦
Control circuit wiring and power circuit wiring should be separated from each other, can not be
placed in the same cell line pipe in order to avoid possible interference.
♦
Control loop should be selected with the multi-layer shielding cored wire, so as to reduce or avoid
the electromagnetic interference.