Yatai Inverter YTB-S-LT User’s Manual
When the 5-00
=
4, this parameter is valid. The operating velocity of the extra-feeding motor is proportional
to the velocity of the winding motor, so for various yarn the user should set the different and appropriate
proportional coefficient to meet the sufficient extra-feeding amount. For instance, in this mode firstly need
to preset the velocity of the extra-feeding motor, otherwise would cause the yarn broken. If the velocity of
winding is predict 500m/min after completing the start-up process and the Tracking Coefficient 5-13=1.20,
then the setting value of 5-01=500*1.2
=
600m/min. In order to make the pressure roll reflect the velocity
better, it is needed to begin its control after delay automatically a period of time (about 10 seconds).
5-14 The Star-up Frequency of
the Extra-feeding Motor
Setting Range
:
0.00
~
25.00Hz
Factory Value
:
0.00
This parameter is used to increase the initial operating frequency, convenient for the start-up of the
Extra-feeding motor. It is applicable to the situation with d
ifficult start-up of
Extra-feeding motor
.
5-15 Extra-feeding Braking
Voltage
Setting Range
:
0
~
60 V
Factory Value
:
40
5-16 Extra-feeding Braking
Time
Setting Range
:
0.0
~
10.0 Sec
Factory Value
:
0.5
5-17 Extra-feeding Braking
Starting Frequency
Setting Range
:
0.00
~
10.00 Hz
Factory Value
:
5.00
When needing the braking, such three parameters are valid. The Braking Voltage and the Braking time are