background image

  Yatai  Inverter                                                                  YTB-S-LT  User’s  Manual

 

参数设置成功

Success of parameter setting 

4.3 Illustration of the Display Items 

Table 4-3                                    List of the display Items   

Display Item 

Illustration 

Process of the power on to reset, after reset the value of length is displayed. 

-YT- 

60.00 

Current operating frequency, parameter’s setting value and so on. 

1000 

Display the current length of the spinning yarn.   

0-00 Function 

code 

Prompt of the spindle full, need to replace the spindle 

OVER 

 

Prompt of the yarn broken, need to connect yarn again. 

Over-current protection instruction for the p

rimary winding motor, the output 

OC 

current is too large

Fault

 

Over-current protection instruction for

 Extra-feeding motor, the output current 

is too large

Fault

 

OC1 

Over-voltage protection instruction, voltage at DC side is too high (Fault) 

OE 

 

Under-voltage protection instruction, voltage at DC side is too low (Fault) 

PO 

 

Overload protection instruction, the load is over weight.

 

OL 

Err1 

Prompt the error of the incorrect password that the user entered. 
Have no detected the Hall pulse of machine halt

 instruction

 when operated 

time is passed the setting value of 4-02 or in the PI control the velocity is 
too low. 

Err2 

Communication Breakdown 

Err3 

 

Err4 

External Storage Breakdown

 

The Factory Values are being restored and display of dT…expresses that the 
data are in communication.

 

dT

。。。

rSt 

Prompt of the forcible reset 

Sequence of the keyboard controller’s display

Current Length

Setting Length

Current Frequency

Extra-feeding Display

Function Code

Current Length. 

PI Control:  Current Length

Setting Length

Current Velocity

Extra-feeding Display

Function Code

Current Length. 

 

Содержание YTB-S-LT-0.4KW

Страница 1: ...A YTB S LT Model Special Frequency Converter for Bobbin Winder User s Manual Shanghai Yatai Instrumentation Limited Company...

Страница 2: ...d Display 4 1 Keyboard Controller 4 2 Setting of the Function Parameters 4 3 Illustration of the Display Items 5 Parameters and Function Codes 5 1 Parameters and the Zoom Table of Function Codes 5 2 D...

Страница 3: ...ter the converter is power on strictly forbid to touch the terminals electrified Otherwise it will jeopardize the personal safety Before wiring and maintenance must turn off the power supply Otherwise...

Страница 4: ...e converter is correct and the other electrical equipments are aging Electrical insulation strength must be checked before installing and operating the converter When the motor is frequently used in t...

Страница 5: ...aptive Main Motor Power 0 4KW Bobbin Winder Type of Input Voltage S Single Phase 220VAC Input Product Series 2 2 The List Table of the YTB S LT Series Products Table 2 1 List Table of the YTB S LT Ser...

Страница 6: ...138 150 YTB S LT 0 4KW 92 105 128 4 5 0 7 6 7 The terminals Cover YATAI INVERTER REV FWD CTC DIGITAL KEYPAD Warning STOP grounding terminal Keyboard Controller PE Mounting Hole Dust Cover Mounting Ho...

Страница 7: ...t up Start up by Keyboard Start by Terminals Operation Machine Halt Machine Halt by Keyboard Machine Halt by Terminals Memory Automatic Memory after Power Off Current Length and Frequency Protection U...

Страница 8: ...gas liquid and no metal particles or metal powder and so on Ambient temperature at 10 50 Level above the sea is less than 1 000 meters Environmental relative humidity must be below 90 with no water co...

Страница 9: ...Terminals Notice The tightening torque moment of the control terminals is 5kgf cm Table 3 3 Brief Introduction to the Control Terminals Classifica tion Terminal Name Factory Function Function Explanat...

Страница 10: ...inal shorts with CM then the frequency OP1 Operating Terminal converter can be in running This terminal coordinates with and 12V and CM can be used as an input port for the pulse signal Pulse Terminal...

Страница 11: ...recommended to adopt the shielding line 3 OUT1 OUT2 are connected to indicator or relay externally 12V INV AFM ING OP4 OP3 OP2 OP1 CM RUN FWD DGT FRQ SCK 5V OUT2 OUT1 GND 12V 220V L1 L2 W V U PE M1 A...

Страница 12: ...ase 220V 2KVA 9A 0 75KW 4 5 2 5 YTB S LT 0 75KW The longest distance of input and output lines ought to be within 300 meters in order to ensure the electromagnetic compatibility requirements Control c...

Страница 13: ...arameter modifying status pushing down this key will return to the display mode of Function Code Edit without saving the modified data LED display operating frequency velocity function code parameter...

Страница 14: ...n change the parameters of the function code to carry out different applications After power on again if user needs to set the parameters he must input firstly the user s password the factory setting...

Страница 15: ...return to the current function code Push the Mode key to display function code but the changed value is invalid 2000 or 0 05 Operations in Table 4 2 are indicated in Figure 4 2 Figure 4 2 The Diagram...

Страница 16: ...lt OC1 Over voltage protection instruction voltage at DC side is too high Fault OE Under voltage protection instruction voltage at DC side is too low Fault PO Overload protection instruction the load...

Страница 17: ...of other parameters can refer to the illustrations above Please don t try to modify the parameters that are unwanted to alter In operating please take notice of that the start up and machine halt of...

Страница 18: ...Function 0 00 User Password 0 9999 Non 8 0 01 Acceleration Time 0 1 300 0 Second 3 0 0 02 Deceleration Time 0 1 300 0 Second 3 0 0 03 Carrier Frequency 2 10 KHz 3 0 04 Compensation Torque Curve 1 18 N...

Страница 19: ...of the Yarn 1 05 Meter 0 1 Yarn Length Setting of the length 10 2 Yarn Length Setting of the length 100 Factory Function Function Setting Range Unit Change Code Value Illustration 2 00 Starting Freque...

Страница 20: ...lt Indication of Yarn broken Output 1 Indication of Spindle full 2 Indication of Adjustable Machine Halt Output Non 0 4 04 OUT1 Output Lasting Time 0 0 10 0 Sec 5 0 4 05 OUT2 Selection of Output Termi...

Страница 21: ...utput Ratio Coefficient 4 13 0 100 0 Output Modify Coefficient 4 14 1 200 100 Factory Function Function Setting Range Unit Change Code Value Illustration 5 00 Setting of the operating Mode of the Extr...

Страница 22: ...on 6 1 18 Compensation 0 Machine Halt with Deceleration Selection of the Extra feeding Motor Operation in the Yarn broken 5 07 Non 0 1 Machine Halt with high speed 2 Machine Halt with Direct Current B...

Страница 23: ...only in the machine halt state but cannot modify in the operating state and can modify the parameters on debug probation After finishing the process of debug please do not modify again the parameters...

Страница 24: ...f that it is easy to jump to OE protection 0 03 Carrier Frequency Factory Value 3 Setting Range 2 10 KHz Carrier Frequency is namely the chopper frequency which means the pulse frequency of PWM waves...

Страница 25: ...rict District of Function Code 1 When 0 06 2 selecting frequency swing control mode to operate its detailed function code setting can be seen in the introduction to the frequency control district Dist...

Страница 26: ...res the extent by control every time with larger than the last one he can set the parameter 1 00 as a slight large value but inappropriate too large if that it is easy to produce oscillation else shou...

Страница 27: ...tance if 0 05 is set up as 1000 and 1 05 is set up as 0 then the length of the spinning yarn is with the maximum value of 1000m and the display length is with the minimum value is 1 m otherwise if the...

Страница 28: ...of machine halt The Starting Frequency refers to the frequency of the spindle full as shown in Figure B For instance if the Starting Frequency is 60Hz and the Stopping Frequency is 40Hz then along wit...

Страница 29: ...g 200 pulses then can increase the length value increasing one unit Therefore by expansion of this double length coefficient it can increase the counting length user can set up it according to the spe...

Страница 30: ...e parameters the acceleration and deceleration time are easy to be too long If the acceleration and deceleration time are too long then the amplitude of the operating frequency is unable to achieve th...

Страница 31: ...e swing frequency function in the district of the function code 2 4 02 Delay Machine Halt Time without Pulse Setting Range 1 0 10 0 S Factory Value 5 0 In operating of the converter the spinning lengt...

Страница 32: ...4 05 1 only in the machine halt mode between OUT2 and 12V there are 12V to output Setting Range 4 09 Selection of the Yarn broken 0 Clear the Mark of Yarn broken by pushing the Reset Key Factory Value...

Страница 33: ...able over too The Factory Value is 50 User can adjust it by his need Function Code 5 District the setting District of the Extra feeding parameters Setting Range 0 Extra feeding is invalid 1 Constant V...

Страница 34: ...m the Stopping Frequency Function code 5 10 until to the Extra feeding Starting Frequency Function Code 5 09 and the yarn bobbin is in spindle full Interrelated Function Code 5 00 6 5 09 5 10 and 2 02...

Страница 35: ...equency at the same time and while the winding motor decreases to 0 Hz the extra feeding motor also decreases to 0Hz simultaneously 5 05 Extra feeding Carrier Wave Frequency Setting Range 2 10 KHz Fac...

Страница 36: ...motor both stop and will reset when machine fault short circuit 3 seconds will start up the mandatory reset 5 08 1 Shorting circuit the terminals of OP3 and CM the winding motor stops and the extra fe...

Страница 37: ...coefficient should be consistent with the unit of 1 05 namely the representative units of length should be same each other 5 11 The Increase Value of the Winding Length Setting Range 1 200 m Factory...

Страница 38: ...e roll reflect the velocity better it is needed to begin its control after delay automatically a period of time about 10 seconds 5 14 The Star up Frequency of the Extra feeding Motor Setting Range 0 0...

Страница 39: ...ncrease Frequency Decrease Progressively 0 06 0 Tracking of the Velocity 5 00 4 Without the Extra feeding Motor 5 00 0 Constant Velocity 5 00 1 Variable Velocity 5 00 2 5 00 4 Tracking of the Velocity...

Страница 40: ...urce When finished the wiring it is to be sure that inside the converter and on the field must put in order The converter must be operated by the specially trained technicians 6 1 3 Debugging with Pow...

Страница 41: ...Notice when wiring again must cut off the power supply 4 Observing the operating status of the yarn spindle Analyze the degree of tightness and mellowness of the yarn spindle and refer to the paramet...

Страница 42: ...isplay Illustration Cause Measures to Deal With Over Current OC Winding Too short Increase Time Increase the acceleration time OC1 Extra feeding Short Circuit on the output side Whether the motor cabl...

Страница 43: ...cuit on the input side Inspect the Input Lines Too low capability of the Air Switch Inspect the capability of the air switch Overload the Motor Decrease the load 7 2 Motor Faults and Its Corrective Me...

Страница 44: ...od ventilation and cooling Clea r the cooling fan and inspect whether or not the operation of the converter is normal Clear the dust and other sundries in the cooling plates at regular intervals Inspe...

Страница 45: ...irs as following are occurred a certain amount of maintenance costs will be collected Operating not according to the requirement of the user manual to cause the mechanical failure or damage After purc...

Страница 46: ...chuan Road North Shanghai China Phone 021 51053128 51053913 Fax 021 51053123 Postal Code 200081 Production Base 128 Zhen Yuan Road Baoshan City Industrial Park Shanghai China Phone 021 36160825 361636...

Отзывы: