Yatai Inverter YTB-S-LT User’s Manual
broken.
5-07
=
1: After yarn broken, the Extra-feeding motor stops its operation in the mode of fast machine halt. It
is applicable to the situation with the requirement to stop the Extra-feeding motor rapidly.
5-07
=
2: After yarn broken, the Extra-feeding motor stops its operation in the mode of fast machine halt
with braking; the braking voltage and braking time are determined by the function code of 5-15 and 5-16. It
is applicable to the situation that the fast machine halt can not satisfy the user’s requirement.
Setting Range
:
0: Machine Halt, Reset and
Forcible Reset
5-08 Selection of the Function
OP3
Factory Value
:
0
1: Reset and Extra-feeding Fast
Stop
2: Reset and Extra-Feeding
Braking
5-08
=
0: Shorting circuit the terminals of OP3 and CM, the winding motor and the extra-feeding motor
both stop and will reset when machine fault, short-circuit 3 seconds will start up the
mandatory reset
.
5-08
=
1: Shorting circuit the terminals of OP3 and CM, the winding motor stops and the extra-feeding
motor is in fast stop and will reset when machine fault, short-circuit 3 seconds will start up the mandatory
reset.
5-08
=
2: Shorting circuit the terminals of OP3 and CM, the winding motor stops and the extra-feeding
motor is in fast stop with braking. The braking voltage and the braking time are determined by the function
codes of 5-15 and 5-16 and will reset when machine fault, short-circuit 3 seconds will start up the
mandatory reset.
5-09 Extra-feeding Starting
Frequency
Setting Range
:
5-14
~
5-10
Factory Value
:
50.00
5-10 Extra-feeding Stopping
Frequency
Setting Range
:
5-10
~
75.00Hz Factory
Value
:
60.00
When 5-00
=
3
,
it is similar to increase progressively frequency control mode in the main winding. It is
applicable to the situation of the winding motor with constant frequency and the extra-feeding motor with