Model
Manufacturer: Bussmann
Model
Fuse Ampere Rating (A)
2A0169
FWH-350A
350
2A0211
FWH-400A
400
2A0273
FWH-450A
450
2A0343
FWH-600A
600
2A0396
FWH-600A
600
Three-Phase 400 V Class
4A0005
FWH-40B
40
4A0008
FWH-40B
40
4A0011
FWH-45B
45
4A0014
FWH-45B
45
4A0021
FWH-60B
60
4A0027
FWH-60B
60
4A0034
FWH-125B
125
4A0040
FWH-150B
150
4A0052
FWH-200B
200
4A0065
FWH-225A
225
4A0077
FWH-225A
225
4A0096
FWH-225A
225
4A0124
FWH-250A
250
4A0156
FWH-300A
300
4A0180
FWH-350A
350
4A0240
FWH-400A
400
4A0302
FWH-600A
600
4A0361
FWH-800A
800
4A0414
FWH-800A
800
4A0480
FWH-700A
700
4A0590
FWH-1000A
1000
n
Grounding
The drive is designed to be used in T-N (grounded neutral point) networks. If installing the drive in other types of grounded
systems, contact your Yaskawa representative for instructions.
n
Guarding Against Harmful Materials
When installing IP00/Open Type enclosure drives, use an enclosure that prevents foreign material from entering the drive
from above or below.
u
EMC Guidelines Compliance
This drive is tested according to European standards IEC/EN 61800-3: 2004.
n
EMC Filter Installation
Note:
Drive models 2A0011 to 2A0273 and 4A0005 to 4A0302 have a built-in EMC filter.
The following conditions must be met to ensure continued compliance with guidelines.
Refer to EMC Filters on page 82
for EMC filter selection.
Installation Method for 2A0011 to 2A0273 and 4A0005 to 4A0302
Verify the following installation conditions to ensure that other devices and machinery used with this drive comply with EMC
guidelines.
1.
Move the screws to the ON position to enable the internal EMC filter.
2.
Use braided shield cable for the drive and motor wiring, or run the wiring through a metal conduit.
3.
Keep wiring as short as possible. Ground the shield on both the drive side and the motor side.
i.9 Standards Compliance