2 Mechanical Installation
YASKAWA Europe
TOMP_C710606_75A V1000 IP66 - Quick Start Guide
EN 7
2
Mechanical Installation
Installation Environment
For optimum performance life of the drive, install the drive in an environment that meets the conditions listed below.
NOTICE:
Never allow a constant stream of the solvent or chemicals listed above to be sprayed directly onto the drive.
Installation Orientation and Spacing
Always install the drive in an upright position. Leave space around the unit for proper cooling as shown in the figure on the right.
Note:
V1000 Series IP66 Type should not be installed using the Side-by-Side method possible with other models.
Environment
Conditions
Installation Area
Indoors
Ambient Temperature
-10
q
C to +40
q
C
Drive reliability improves in environments without wide temperature fluctuations.
Storage Temperature
-20
q
C to +60
q
C
Temperature conditions allowable for short-term transport.
Surrounding Area
Install the drive in an area free from:
• oil mist
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases
• excessive vibration
• direct sunlight
The surrounding area can contain the following chemicals and solvents.
(Reagent)
• Hydrochloric acid (10%)
• Sulfuric acid (10%)
• Nitric acid (10%)
• Ammonia water
• Sodium chloride
(Solvent)
• Methanol
• Ethanol
Altitude
1000 m or less
Vibration
10 - 20 Hz at 9.8 m/s
2
, 20 - 55 Hz at 5.9 m/s
2
Orientation
Install the drive vertically to maintain maximum cooling effects.
30mm
30mm
100mm
100mm
Air
Air
.
IP6 6
V 1000
TOMP_C710606_75A_0_0_prePrint.pdf 39
21.12.2010 13:52:21