![YASKAWA SOLECTRIA XGI 1000 Series Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/yaskawa/solectria-xgi-1000-series/solectria-xgi-1000-series_installation-and-operation-manual_907570067.webp)
Installation and Operation Guide SOLECTRIA XGI 1000
DOCR-070733-F (2/22/2021)
Page 67 of 78
26
Communication 2
Fault
Communication processor application
fault.
Power cycle the inverter. If the
inverter does not clear the error,
contact Technical Support.
27
Communication 3
Fault
Communication processor hardware
fault.
Power cycle the inverter. If the
inverter does not clear the error,
contact Technical Support.
28
Network Fault
A network connection has failed.
Check to make sure the Ethernet
connections are firmly seated. Check
the Wi-Fi antennas, ensure they are
vertically mounted.
29
Software Update
Fault
Communication processor software
update fault.
Power cycle the inverter. If the
inverter does not clear the error,
contact Technical Support.
30
Unauthorized
Network Access
An unauthorized attempt to access
the network has occurred.
Check whether there have been any
malicious attempts to access the
inverter network.
31
Invalid Configuration
Request
An external request to adjust setting
beyond the allowable limits.
Check that the value being entered is
acceptable and re-enter.
32
Reserved