9.5 Analog Monitor
9-27
9
9.5.1 Related Parameters
The following signals can be monitored.
(1) Pn003: Function Selections
* When using speed control or torque control, the position error monitor signal is not specified.
The analog monitor output voltage is ±5 V (maximum). The output will be limited to
±5 V even if this value is exceeded
in the above calculations.
Parameter
Function
Monitor 1
Monitor 2
Monitor Signal
Observation Gain
Remarks
Pn003
n.
0
n.
0
Motor speed
1 V / 1000 min
-1
Factory setting for Monitor 2
n.
1
n.
1
Speed reference
1 V / 1000 min
-1
−
n.
2
n.
2
Internal torque reference
1 V / 100% rated torque
Factory setting for Monitor 1
n.
3
n.
3
Position error
∗
0.05 V / 1 reference unit
−
n.
4
n.
4
Position error
∗
0.05 V / 100 reference units
−
n.
5
n.
5
Position reference speed
(converted to motor speed)
1 V / 1000 min
-1
−
n.
6
n.
6
Motor speed
1 V / 250 min
-1
−
n.
7
n.
7
Motor speed
1 V / 125 min
-1
−
n.
8
n.
8
Reserved. Do not set.
−
−
n.
9
n.
9
−
n.
A
n.
A
−
n.
B
n.
B
−
n.
C
n.
C
−
n.
D
n.
D
−
n.
E
n.
E
−
n.
F
n.
F
−