6.3 Examples of I/O Signal Connections
6-15
6
(2) Sequence Input Circuit Interface
CN1 connector terminals 11 to 18 is explained below.
The sequence input circuit interface connects through a relay or open-collector transistor circuit. Select a low-
current relay otherwise a faulty contact will result.
Note: The 24 VDC external power supply capacity must be 50 mA minimum.
For SEN input signal circuit, refer to
8.4 Absolute Encoders
.
(3) Sink Circuit and Source Circuit
The SERVOPACK’s I/O circuit uses a bidirectional photocoupler. Select either the sink circuit or the source cir-
cuit according to the specifications required for each machine.
(4) Output Circuit Interface
There are three types of SERVOPACK output circuits:
(a) Line Driver Output Circuit
CN1 connector terminals, 20-21: phase-A signal, 22-23: phase-B signal and 24-25: phase-C signal are
explained below.
Encoder serial data converted to two-phase (phases A and B) pulse output signals (PAO, /PAO, PBO, /PBO),
zero-point pulse signals (PCO, /PCO), and the amount of phase-S rotation signal (PSO, /PSO) are output via
line-driver output circuits. Normally, the SERVOPACK uses this output circuit in speed control to comprise
the position control system at the host controller. Connect the line-driver output circuit through a line
receiver circuit at the host controller.
Relay Circuit Example
Open-collector Circuit Example
3.3 k
Ω
/S-ON, etc.
SERVOPACK
24 VDC
+24VIN
+24VIN 3.3 k
Ω
/S-ON, etc.
SERVOPACK
24 VDC
INFO
Sink Circuit
Source Circuit
24 V
SERVOPACK input
+
−
SERVOPACK input
+
−