2.5 Selecting Peripheral Devices
2-13
2
2.5.2 Molded-case Circuit Breaker and Fuse Capacity
Note: 1. Connect the fuse or the molded-case circuit breaker to the DC side on the control power supply.
2. Select a fuse and a molded-case circuit breaker that are certified by the UL and the CSA and have CE
Marking.
d
Digital Operator
JUSP-OP02A-2
With connection cable (1 m (3.28 ft))
5.6.2
e
Connection Cable for Digital Op-
erator
1m
(3.28 ft)
JZSP-CMS00-1
Only required when using
Σ
series
Digital Operator JUSP-OP02A-1.
1.5m
(4.92 ft)
JZSP-CMS00-2
2 m
(6.56 ft)
JZSP-CMS00-3
f
Connection Cable for Personal
Computer
2 m
(6.56 ft)
JZSP-CMS01
D-Sub 25-pin (For PC98)
5.6.1
2 m
(6.56 ft)
JZSP-CMS02
D-Sub 9-pin (For DOS/V)
2 m
(6.56 ft)
JZSP-CMS03
Half-pitch 14-pin (For PC 98)
g
Analog Monitor Cable
1 m
(3.28 ft)
JZSP-CA01 or
DE9404559
5.6.3
h
Battery for Absolute Encoder
ER6VC3
To connect to a host controller (pro-
vided by a customer)
3.6 V 2000 mAh,
manufactured by Toshiba Battery
Co., Ltd.
5.6.8
(cont’d)
Name
Length
Type
Specifications
Refer-
ence
CN3
Operator
end
SERVOPACK
end
CN3
Personal
computer
end
SERVOPACK
end
Personal
computer
end
SERVOPACK
end
Personal
computer
end
SERVOPACK
end
CN5
SERVOPACK
end
Monitor
end
CN8
SERVOPACK
model
Voltage
Capacity
(W)
Power Supply Capacity per
SERVOPACK (kVA)
Current Capacity of the Fuse and the
Molded-case Circuit Breaker
Continuous
Rating (W)
Momentary
Rating (W)
Power Supply
100 VAC (Arms)
Power Supply
200 VAC (Arms)
SGDJ-A5C
24 VDC
50
96.6
220
15
7.5
SGDJ-A8C
80
144
320
20
10
SGDJ-A5E
48 VDC
50
92.1
210
15
7.5
SGDJ-01E
100
170
380
22
11
SGDJ-02E
200
322
700
40
20
SGDJ-03E
300
467
1000
60
30
Содержание SGDJ Series