9 Adjustments
9.2.4 Machine Rigidity Setting for Online Autotuning
9-8
9.2.4 Machine Rigidity Setting for Online Autotuning
There are ten machine rigidity settings for online autotuning. When the machine rigidity setting is selected, the
servo gains (Speed Loop Gain, Speed Loop Integral Time Constant, Position Loop Gain, and Torque Reference
Filter Time Constant) are determined automatically. The factory setting for the machine rigidity setting is 4. The
speed loop is suitable for PI or I-P control.
When parameter Pn10B.1 is 0, PI control will be used and when Pn10B.1 is 1, I-P control will be used. To vali-
date the setting, however, the power supply must be turned OFF and then back ON.
After having validated the setting, always set the machine rigidity setting.
When setting the machine rigidity after having changed the position loop gain (Pn102), the value closest to the
set position loop gain is displayed as the initial value of machine rigidity.
• Speed Loop PI Control
If the machine rigidity setting is greater, the servo gain will increase and positioning time will decrease. If the
setting is too large, however, vibration may result depending on the machine configuration. Set the machine
rigidity starting at a low value and increasing it within the range where vibration does not occur.
Machine Rigidity
Setting
Fn001
Position Loop Gain
[s
-1
]
Pn102
Speed Loop Gain
[Hz]
Pn100
Speed Loop Integral
Time Constant
[0.01 ms]
Pn101
Torque Reference
Filter Time Constant
[0.01 ms]
Pn401
1
15
15
6000
250
2
20
20
4500
200
3
30
30
3000
130
4
40
40
2000
100
5
60
60
1500
70
6
85
85
1000
50
7
120
120
800
30
8
160
160
600
20
9
200
200
500
15
10
250
250
400
10