2-5
166006-1CD
166006-1CD
2
Installation
2.3 Positioner Installation
RM2-755/1255SL
Positioner
2.3.1.1 Location
Make sure Positioner is installed, with the following conditions:
• Ambient Temperature: 0° to +45°C
• Humidity: 20% to 80% RH (non-condensing)
• Free from dust, soot, or water
• Free from corrosive gas or liquid, or explosive gas
• Free from excessive vibration (Vibration acceleration: 4.9m/s
2
[0.5G] or less)
• Free from large electrical noise (plasma)
• Flatness for installation: 0.5mm or less
• Ensure appropriate space for equipment by reviewing
“Mounting the Positioner to the Floor”
1255SL Positioner Technical Specifications” on page 4-1
other additional documentation as required.
CAUTION
• Install the Positioner in a location where the Positioner with a jig
does not hit against anything such as the wall or any safeguards.
Failure to observe this warning may result in damage.