4.2 Using the Digital Operator
110
YASKAWA ELECTRIC
TOEP C710687 02B FSDrive-MV1000 Instructions
u
LCD Display
Figure 4.2
Figure 4.2 LCD Display
Table 4.1 Display and Contents
No.
Name
Display
Content
1
Operation Mode Menus
MODE
Displayed when in Mode Selection.
MONITR
Displayed when in Monitor Mode.
VERIFY
Indicates the Verify Menu.
PRMSET
Displayed when in Parameter Setting Mode.
A.TUNE
Displayed during Auto-Tuning.
SETUP
Displayed when in Setup Mode.
2
Mode Display Area
DRV
Displayed when in Drive Mode.
PRG
Displayed when in Programming Mode.
3
Ready
Rdy
Indicates the drive is ready to run.
4
Data Display
−
Displays specific data and operation data.
5
Frequency
Reference
Assignment
<1> Displayed when in Frequency Reference Mode.
<2> Displayed when in Frequency Reference Mode and Monitor Mode.
OPR
Displayed when the frequency reference is assigned to the Digital Operator Option.
AI
Displayed when the frequency reference is assigned to the drive’s Analog Input of the drive.
COM
Displayed when the frequency reference is assigned to the drive’s MEMOBUS/Modbus
Communication Inputs of the drive.
OP
Displayed when the frequency reference is assigned to an drive Option Unit.
6
LO/RE
Display
RSEQ
Displayed when the run command is supplied from a remote source.
LSEQ
Displayed when the run command is supplied from the digital operator keypad.
RREF
Displayed when the frequency reference is supplied from a remote source.
LREF
Displayed when the frequency reference is supplied from the digital operator keypad.
7
Function Key 1
(F1)
JOG
Pressing
executes the Jog function.
HELP
Pressing
displays the Help menu.
←
Pressing
scrolls the cursor to the left.
HOME
Pressing
returns to the top menu (Frequency Reference).
ESC
Pressing
returns to the previous display.
8
FWD/REV
FWD
Indicates forward motor operation.
REV
Indicates reverse motor operation.
9
Function Key 2
(F2)
FWD/REV
Pressing
switches
between forward and reverse.
DATA
Pressing
scrolls to the next display.
→
Pressing
scrolls the cursor to the right.
RESET
Pressing
resets the existing drive fault or error.
㪴
RSEQ
RREF
1
2
3
9
8
7
6
5
4
(AI)
60.00
Hz
F1
F1
F1
F1
F1
F2
F2
F2
F2
Содержание FSDrive-MV1000 Series
Страница 8: ...8 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 38: ...1 4 Component Names and Configurations 38 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 106: ...3 9 Wiring Check 106 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 136: ...4 9 Checking and Saving Parameter Default Values 136 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 210: ...6 7 Spare Parts 210 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 222: ...B 1 European Standards 222 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...