4 Operation
4.5.3 Limitations
4-24
4.5.3
Limitations
The following functions cannot be used during the test without a motor.
• Brake output signal (The brake output signal can be checked with the I/O signal monitor function of the Sig-
maWin+.)
• Items marked with "
×
" in the following utility function table.
Note:
: Can be used
×
: Cannot be used
Fn No.
Contents
Can be
used or not
Motor not
connected
Motor
connected
Fn000
Alarm history display
Fn002
JOG operation
Fn003
Origin search
Fn004
Program JOG operation
Fn005
Initializing parameter settings
Fn006
Clearing alarm history
Fn008
Absolute encoder multiturn reset and encoder alarm reset
×
Fn00C
Offset adjustment of analog monitor output
Fn00D
Gain adjustment of analog monitor output
Fn00E
Automatic offset-signal adjustment of the motor current detection signal
×
Fn00F
Manual offset-signal adjustment of the motor current detection signal
×
Fn010
Write prohibited setting
Fn011
Servomotor model display
Fn012
Software version display
Fn013
Multiturn limit value setting change when a multiturn limit disagreement alarm
occurs
×
Fn01B
Vibration detection level initialization
×
×
Fn01E
Display of SERVOPACK and servomotor ID
Fn030
Software reset
Fn200
Tuning-less levels setting
×
×
Fn201
Advanced autotuning
×
×
Fn202
Advanced autotuning by reference
×
×
Fn203
One-parameter tuning
×
×
Fn204
Anti-resonance control adjustment function
×
×
Fn205
Vibration suppression function
×
×
Fn206
EasyFFT
×
×
Fn207
Online vibration monitor
×
×