8.1 Alarm Displays
8-9
8
Trou
blesh
ooting
A.810:
Encoder Backup Error
(Only when an absolute
encoder is connected.)
(Detected on the encoder
side.)
Alarm occurred when the power
to the absolute encoder was ini-
tially turned ON.
Check to see if the power was
turned ON initially.
Set up the encoder (Fn008).
The encoder cable disconnected,
and connected again.
Check to see if the power was
turned ON initially.
Confirm the connection and set up
the encoder (Fn008).
The power from both the control
power supply (+5 V) from the
SERVOPACK and the battery
power supply is not being sup-
plied.
Check the encoder connector bat-
tery or the connector contact status.
Replace the battery or take similar
measures to supply power to the
encoder, and set up the encoder
(Fn008).
An absolute encoder fault
occurred.
−
If the alarm cannot be reset by set-
ting up the encoder again, replace
the servomotor.
A SERVOPACK fault occurred.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.820:
Encoder Checksum
Error
(Detected on the encoder
side.)
An encoder fault occurred.
−
• Absolute encoder
Set up the encoder again using
Fn008. If the alarm still occurs,
the servomotor may be faulty.
Replace the servomotor.
• One-turn absolute encoder or
incremental encoder
The servomotor may be faulty.
Replace the servomotor.
A SERVOPACK fault occurred.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.830:
Absolute Encoder
Battery Error
(The absolute encoder
battery voltage is lower
than the specified value.)
The battery connection is incor-
rect.
Check the battery connection.
Reconnect the battery.
The battery voltage is lower than
the specified value 2.7 V.
Measure the battery voltage.
Replace the battery.
A SERVOPACK fault occurred.
−
The SERVOPACK may be faulty.
Replace the SERVOPACK.
A.840:
Encoder Data Error
(Detected on the encoder
side.)
An encoder malfunctioned.
−
Restart the SERVOPACK. If the
alarm still occurs, the servomotor
may be faulty. Replace the servo-
motor.
Malfunction of encoder because
of noise interference, etc.
−
Correct the wiring around the
encoder by separating the encoder
cable from the servomotor main cir-
cuit cable or by checking the
grounding and other wiring.
A.850:
Encoder Overspeed
(Detected when the con-
trol power supply was
turned ON.)
(Detected on the encoder
side.)
The servomotor speed is higher
than 200 min
-1
when the control
power supply was turned ON.
Check the motor rotating speed
(Un000) to confirm the servomotor
speed when the power is turned ON.
Reduce the servomotor speed to a
value less than 200 min
-1
, and turn
ON the control power supply.
An encoder fault occurred.
−
Restart the SERVOPACK. If the
alarm still occurs, the servomotor
may be faulty. Replace the servo-
motor.
A SERVOPACK fault occurred.
−
Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
(cont’d)
Alarm Number:
Alarm Name
(Alarm Description)
Cause
Investigative Actions
Corrective Actions