9 Appendix
9.1.2 Parameters
9-20
Pn553
2
Analog Monitor Magnifica-
tion (
×
2)
-10000 to
10000
×
0.01
100
Immediately
Setup
5.1.3
Pn560
2
Remained Vibration Detec-
tion Width
1 to 3000
0.1%
400
Immediately
Setup
5.7.1
Pn561
2
Overshoot Detection Level
0 to 100
1%
100
Immediately
Setup
5.3.1,
5.4.1
Pn600
2
Reserved (Do not change.)
–
–
0
–
–
–
Pn601
2
Reserved (Do not change.)
–
–
0
–
–
–
Pn800
2
Communications Control
–
–
0040
Immediately
Setup
*1
∗1.
For details, refer to
Σ
-V Series User’s Manual MECHATROLINK-II Commands
(Manual No.: SIEP S800000 54).
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
4th 3rd 2nd 1st
digit digit digit digit
n.
MECHATROLINK-
II
Communications Check Mask (for debug)
0
No mask
1
Ignores MECHATROLINK communications error (A.E60).
2
Ignores WDT error (A.E50).
3
Ignores both MECHATROLINK communications error (A.E60) and WDT error (A.E50).
Warning Check Mask
0
No mask
1
Ignores data setting warning (A.94 ).
2
Ignores command warning (A.95 ).
3
Ignores both data setting warning (A.94 ) and command warning (A.95 ).
4
Ignores communications warning (A.96 ).
5
Ignores both data setting warning (A.94 ) and communications warning (A.96 ).
6
Ignores both command warning (A.95 ) and communications warning (A.96 ).
7
Ignores data setting warning (A.94 ), command warning (A.95 ) and communications
warning (A.96 ).
Reserved (Do not change.)