9.1 List of Parameters
9-5
9
Ap
pend
ix
Pn007
2
Application Function Select
Switch 7
0000 to 005F
−
0000
Immediately
Setup
5.1.3
Pn008
2
Application Function Select
Switch 8
0000 to 7121
−
4000
After restart
Setup
−
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Analog Monitor 2 Signal Selection
00
Motor rotating speed (1 V / 1000 min
-1
)
01
Speed reference (1 V / 1000 min
-1
)
02
Torque reference (1 V/100% rated torque)
03
Position error (0.05 V/1 reference unit)
04
Position amplifier error (after electronic gears) (0.05 V/ 1 encoder pulse unit)
05
Position reference speed (1 V / 1000 min
-1
)
06
Reserved (Do not change.)
07
Reserved (Do not change.)
08
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
09
Reserved (Do not change.)
0A
Torque feedforward (1 V/100% rated torque)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C
Completion of position reference (completed: 5 V not completed: 0 V)
0D
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Lowered Battery Voltage Alarm/Warning Selection
Reference
Section
0
Outputs alarm (A.830) for lowered battery voltage.
4.7.3
1
Outputs warning (A.930) for lowered battery voltage.
Reserved (Do not change.)
Reserved (Do not change.)
Warning Detection Selection
Reference
Section
0
Detects warning.
8.2.1
1
Does not detect warning.
4th 3rd 2nd 1st
digit digit digit digit
n.