5.6 Anti-Resonance Control Adjustment Function (Fn204)
5-63
5
Adjustments
5.6.3
Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using S while this function is being executed.
No : Parameters cannot be changed using S while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Name
Mid-execution
changes
Automatic
changes
Pn160
Anti-Resonance Control Related Switch
Yes
Yes
Pn161
Anti-Resonance Frequency
No
Yes
Pn162
Anti-Resonance Gain Compensation
Yes
No
Pn163
Anti-Resonance Damping Gain
No
Yes
Pn164
Anti-Resonance Filter Time Constant 1 Compensation
Yes
No
Pn165
Anti-Resonance Filter Time Constant 2 Compensation
Yes
No