14 Specifications
YASKAWA ELECTRIC
SIEP C730600 43A YASKAWA AC Drive-Option Card DeviceNet Technical Manual
75
14
Specifications
Specifications
Table 23 Option Specifications
Revision History
The revision dates and the numbers of the revised manuals appear on the bottom of the back cover.
Items
Specifications
Model
SI-N3
SI-N3 Supported Messages
Group 2 Server (UCMM capable)
Explicit Messages: Fragmentation is supported. Up to 32 bytes can be input and output.
Polled I/O Messages: Fragmentation is not supported. Up to 8 bytes can be input and output.
Faulted Node Recovery / Offline Connection Set Messages / Automatic Device Replacement (ADR)
Change of State Message (COS).
COS can be used as an I/O Input Assembly.
I/O Assembly Instance
Input: 17 types (4~8 bytes)
Output: 18 types (4~8 bytes)
DeviceNet Specification
Conformance Level 19: Passed
DeviceNet Profile
AC Drive
Input Power
Voltage: 11~25 Vdc
Current: 40 mA
Connector Type
5-pin open-style screw connector
Physical Layer Type
Isolated Physical Layer
CAN trans photocoupler
MAC ID Setting
Programmable from drive keypad or network:
MAC ID 0 to 63
Communications Speed/Baud Rate
Programmable from drive keypad or network:
125/250/500 k bit/s
Auto Baud Rate
Idle Mode Detect
Heartbeat
Ambient Temperature
–10
°
C to +50
°
C
Humidity
up to 95% RH (no condensation)
Storage Temperature
–20
°
C to +60
°
C (allowed for short-term transport of the product)
Area of Use
Indoor (free of corrosive gas, airborne particles, etc.)
Altitude
up to 1000 m
Date of Publication Revision Number Section
Revised Content
August 2008
−
−
First edition
MANUAL NO.
ޓ
SIEP C730600 43A
Published in Japan August 2008 08-8
Date of
publication
Date of original
publication
Содержание DeviceNet SI-N3
Страница 2: ...This Page Intentionally Blank...