11.2
Specifications of Options and Peripheral Devices
- 7
Frequency Meter Specifications
Code No.
Model No.
JVOP-96 2
73041-0906X-02
DCF-6A 3 V 1 mA 150 Hz
JVOP-96 3
73041-0906X-03
DCF-6A 3 V 1 mA 220 Hz
The following Option Cards are available.
Table
11.4
Option Cards
Type
Name
Code No.
Descriptions
Manual No.
Analog Reference Card
AI-14U
73600-C001X
Used to set high-accuracy, high-resolution analog speed refer-
ences.
S
Input signal levels: 0 to +10 VDC 20 k
1 channel
4 to 20 mA DC 250
1 channel
S
Input resolution: 14 bits 1/16384
TOE-C736-
30.13
Analog Reference Card
AI-14B
73600-C002X
Used to set high-accuracy, high-resolution analog speed refer-
ences.
S
Input signal level:
0 to 10 VDC 20 k
4 to 20 mA DC 500
3 channels
S
Input resolution: 13 bits + sign 1/8192
TOE-C736-
30.14
Sp
Digital Reference Card
DI-08
73600-C003X
Used to set frequency references in 2-digit BCD or 8-bit binary.
S
Input signal: 8 bits binary
2 digits BCD + SIGN SET signal
S
Input voltage: +24 V insulated
S
Input current: 8 mA
TOE-C736-
30.15
Digital Reference Card
DI-16H2
73600-C016X
Used to set 16-bit digital speed references.
S
Input signal: 16 bits binary
4 digits BCD + SIGN SET signal
S
Input voltage: +24 V insulated
S
Input current: 8 mA
Used to set frequency references with 16 or 12 bits (switchable).
TOE-C736-40.7
Bu
RS-232C/485/422 Interface
Card
SI-K2
73600-C015X
Used to convert RS-232C to RS-485 or RS-422.
Supports baud rates up to 9.6 kbps.
TOE-C736-40.6
Bu
Analog Monitor Card
AO-08
73600-D001X
Converts analog signals to monitor the Inverter’s output status
(output frequency, output current, etc.) to absolute values and
outputs them.
S
Output resolution: 8 bits 1/256
S
Output voltage: 0 to +10 V not insulated
S
Output channels: 2 channels
TOE-C736-
30.21
Analog Monitor Card
AO-12
73600-D002X
Output analog signals to monitor the Inverter’s output status (out-
put frequency, output current, etc.).
S
Output resolution: 11 bits 1/2048 + sign
S
Output voltage: 10 to +10 V not insulated
S
Output channels: 2 channels
TOE-C736-
30.22
Pulse Monitor Card
PO-36F
73600-D003X
Used to output pulse-train signals according to the output frequen-
cy of the Inverter
S
Output pulse: 1F, 6F, 10F, 12F, 36F F: Output frequency
S
Output voltage: +12 V 10% insulated
S
Output current: 20 mA max.
TOE-C736-
30.23
Digital Output Card
DO-08
73600-D004X
Outputs isolated digital signals to monitor the Inverters operating
status (alarm signals, zero speed detection, etc.)
S
Output form: Photocoupler output, 6 channels
48 V 50 mA max.
Relay contact outputs, 2 channels
250 VAC: 1 A max., DC 30V: 1 A max.
TOE-C736-
30.24
2C-Relay Output Card
DO-02C
73600-D007X
Provides two multi-function outputs (DPDT relay contacts) in
addition to those provided by the Inverter.
TOE-C736-40.8
11