7-8
–
+
ELEC
CHECKING THE BULBS AND BULB SOCKETS
CHECKING THE CONDITION OF THE BULB
SOCKETS
The following procedure applies to all of the
bulb sockets.
1. Check:
8
bulb socket (for continuity)
(with the pocket tester)
No continuity
→
Replace.
Pocket tester
YU-03112
NOTE:
Check each bulb socket for continuity in the
same manner as described in the bulb section;
however, note the following.
***************************************
a. Install a good bulb into the bulb socket.
b. Connect the pocket tester probes to the
respective leads of the bulb socket.
c. Check the bulb socket for continuity. If any
of the readings indicate no continuity, re-
place the bulb socket.
***************************************
Содержание YW50AP