INSP
ADJ
3-27
BATTERY INSPECTION
Charging method using a variable-current (voltage) type charger
Measure the open-circuit volt-
age prier to charging.
Connect a charger and AMP
meter to the battery and start
charging.
Make sure the current is higher
than the standard charging
current written on the battery.
Adjust the voltage so that current
is at standard charging level.
Set the timer according to the
charging time suitable for the
open-circuit voltage. Refer to
“Battery condition checking
steps”.
By turning the charging voltage
adjust dial, set the charging volt-
age at 20 - 25 V.
Monitor the amperage for 3-5
minutes to check if the standard
charging current is reached.
If current does
not exceed stan-
dard charging
current after 5
minutes, replace
the battery.
In case that charging requires more than 5 hours, it is advisable to
check the charging current after a lapse of 5 hours. If there is any
change in the amperage, readjust the voltage to obtain the standard
charging current.
NOTE:
Voltage should be measured
30 minutes after the machine
is stopped.
NOTE:
Set the changing voltage at
16-17 V. (If the setting is lower,
charging Will be insufficient.
If too high, the battery Will be
over-charged.)
Measure the battery open-circuit voltage after having left the bat-
tery unused for more than 30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under12.0 V --- Replace the battery.
NO
YES
YES
NO
Charger
AMP
meter