9 - 38
–
+
ELEC
SIGNAL SYSTEM
3.If the reverse indicator light fails to come on:
CONTINUITY
1.Bulb and bulb socket
●
Check the bulb and bulb socket for
continuity.
NO CONTINUITY
Replace the bulb and/or bulb socket.
CONTINUITY
2.Reverse switch
Refer to “CHECKING THE SWITCHES”.
NO CONTINUITY
Replace the reverse switch.
3.Voltage
●
Connect the pocket tester (DC 20 V) to the
bulb socket coupler.
Tester (+) lead
→
Red/White terminal
1
Tester (–) lead
→
Green/Blue terminal
2
MEETS
SPECIFICATION
●
Turn the main switch to “ON”.
●
Check the voltage (12 V).
Replace the CDI unit.
OUT OF SPECIFICATION
The wiring circuit from the main switch to the
bulb socket connector is faulty, repair it.
Содержание YFM400FAR
Страница 1: ...LIT 11616 16 02 5TE F8197 10 YFM400FAR SERVICE MANUAL ...
Страница 36: ...2 11 SPEC Cylinder head tightening sequence Item Standard Limit MAINTENANCE SPECIFICATIONS ...
Страница 48: ...2 23 SPEC 1 Radiator 2 Thermostat È To coolant reservoir COOLANT FLOW DIAGRAMS ...
Страница 49: ...2 24 SPEC OIL FLOW DIAGRAMS 1 Camshaft 2 Crankshaft 3 Drive axle OIL FLOW DIAGRAMS ...
Страница 50: ...2 25 SPEC 1 Oil filter OIL FLOW DIAGRAMS ...
Страница 51: ...2 26 SPEC 1 Oil pump 2 Oil strainer OIL FLOW DIAGRAMS ...
Страница 310: ...9 3 ELEC CHECKING THE SWITCHES ...
Страница 338: ...9 31 ELEC LIGHTING SYSTEM ...
Страница 365: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...
Страница 367: ...LIT 11616 17 32 5UH F8197 10 YFM350FAS SUPPLEMENTARY SERVICE MANUAL ...
Страница 386: ... 12 SPEC Cylinder head tightening sequence Item Standard Limit 5 2 4 1 6 3 MAINTENANCE SPECIFICATIONS ...
Страница 396: ... 22 SPEC OIL FLOW DIAGRAMS 1 Camshaft 2 Crankshaft 3 Oil pump 4 Oil strainer OIL FLOW DIAGRAMS ...
Страница 397: ... 23 SPEC 1 Thermo unit 2 Oil pump 3 Oil filter È To oil cooler É From oil cooler OIL FLOW DIAGRAMS ...
Страница 398: ... 24 SPEC 1 Crankshaft 2 Oil filter OIL FLOW DIAGRAMS ...
Страница 480: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...