8 - 9
–
+
ELEC
CHECKING THE BULBS AND BULB SOCKETS
CHECKING THE CONDITION OF THE BULB
SOCKETS
The following procedure applies to all of the
bulb sockets.
1. Check:
• bulb socket (for continuity)
(with the pocket tester)
No continuity
→
Replace.
NOTE:
@
Check each bulb socket for continuity in the
same manner as described in the bulb section;
however, note the following.
@
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Install a good bulb into the bulb socket.
b. Connect the pocket tester probes to the
respective leads of the bulb socket.
c. Check the bulb socket for continuity. If any
of the readings indicate no continuity,
replace the bulb socket.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
Pocket tester
90890-03112
Содержание VMX12 2001
Страница 1: ...VMX12 2001 3LRD AE1 SERVICEMANUAL ...
Страница 2: ......
Страница 8: ......
Страница 9: ...GEN INFO 1 ...
Страница 11: ...GEN INFO ...
Страница 21: ......
Страница 22: ...SPEC 2 ...
Страница 24: ...SPEC ...
Страница 52: ...2 28 SPEC OIL FLOW DIAGRAMS 1 Camshaft 2 Main gallery 3 Crankshaft 4 Oil level switch ...
Страница 54: ...2 30 SPEC OIL FLOW DIAGRAMS 1 Crankshaft 2 Oil pipe 3 Oil filter ...
Страница 65: ...CHK ADJ 3 ...
Страница 125: ......
Страница 126: ...ENG 4 ...
Страница 130: ...ENG ...
Страница 150: ...4 20 ENG 4 Install timing mark accessing screw 1 crankshaft end cover 2 T R 7 Nm 0 7 m kg CAMSHAFTS ...
Страница 236: ......
Страница 237: ...COOL 5 ...
Страница 239: ...COOL ...
Страница 258: ...CARB 6 ...
Страница 260: ...CARB ...
Страница 272: ......
Страница 273: ...CHAS 7 ...
Страница 389: ......
Страница 390: ...ELEC 8 ...
Страница 396: ...8 4 ELEC SWITCHES ...
Страница 417: ...8 25 ELEC STARTER MOTOR 3 Install O rings 1 bolts 2 New T R 5 Nm 0 5 m kg ...
Страница 445: ...TRBL SHTG 9 ...