9 - 40
–
+
ELEC
4. If the reverse indicator light fails to come on:
CONTINUITY
1. Bulb and bulb socket
• Check the bulb and bulb socket for conti-
nuity.
NO CONTINUITY
Replace the bulb and/or bulb socket.
CONTINUITY
2. Reverse switch
Refer to “CHECKING THE SWITCHES”.
NO CONTINUITY
Replace the reverse switch.
3. Voltage
• Connect the pocket tester (DC 20 V) to the
indicator light assembly 2 coupler.
Tester (+) lead
→
Brown terminal
1
Tester (–) lead
→
Green/Blue terminal
2
Br
B
/
G
Br
W
/
L
Br
W
/
Y
Br B
/
G
Br W
/
Y
Br W
/
L
R
/
W
G
/
L
R/W
L
/
R
R
/
W
Sb
Br G
/
L
Br Sb
Br L
/
R
1
2
MEETS
SPECIFICATION
• Turn the main switch to “ON”.
• Shift the drive select lever into the reverse
gear “R”.
• Check the voltage (12 V).
Replace the C.D.I. unit.
OUT OF SPECIFICATION
The wiring circuit from the main switch to the
reverse switch is faulty, repair it.