9 - 49
–
+
ELEC
TURNS
4. Radiator fan motor
• Disconnect the radiator fan motor coupler.
• Connect the battery (12 V) as shown.
Battery (+) lead
→
Blue terminal
1
Battery (–) lead
→
Black terminal
2
• Check the operation of the radiator fan
motor.
*
DOES NOT TURN
Replace the radiator fan motor.
MEETS
SPECIFICATION
5. Circuit breaker (radiator fan motor)
• Remove the circuit breaker from the wire
harness.
• Connect the pocket tester (
Ω
×
1) to the
circuit breaker.
Circuit breaker resistance
Zero
Ω
at 20 °C (68 °F)
*
OUT OF SPECIFICATION
Replace the circuit breaker.