9 - 3
–
+
ELEC
CHECKING THE SWITCHES
CHECKING THE SWITCHES
Use a pocket tester to check the terminals for
continuity. If the continuity is faulty at any
point, replace the switch.
NOTE:
• Set the pocket tester to “0” before starting
the test.
• The pocket tester should be set to the “
Ω
×
1”
range when testing the switch for continuity.
• Turn the switch on and off a few times when
checking it.
Pocket tester
P/N. YU-03112-C, 90890-03112
CHECKING A SWITCH SHOWN IN THE
MANUAL
The terminal connections for switches (main
switch, light switch, etc.) are shown in a chart
similar to the one on the left.
This chart shows the switch positions in the
column and the switch lead colors in the top
row.
For each switch position, “
” indicates
the terminals with continuity.
The example chart shows that:
1
There is continuity between the “Brown/Blue and
Red” leads when the switch is set to “ON”.
R
L
/
B
Br
/
L
B
OFF
Br
/
L R B L
/
B
ON
START
1
Содержание Rhino 450 YXR45FAV
Страница 1: ...LIT 11616 19 43 2P5 F8197 10 YXR45FAV SERVICE MANUAL ...
Страница 6: ......
Страница 56: ...2 30 SPEC OIL FLOW DIAGRAMS 1 Oil filter cartridge 2 Oil pipe adapter 3 Oil delivery pipe A A A A 1 1 2 3 ...
Страница 57: ...2 31 SPEC OIL FLOW DIAGRAMS 1 Oil delivery pipe 2 Oil pump 3 Oil strainer A A A A 1 2 3 ...
Страница 347: ...9 4 ELEC CHECKING THE SWITCHES ...
Страница 375: ...9 32 ELEC LIGHTING SYSTEM ...
Страница 411: ......
Страница 412: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...