3 - 49
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a variable-current (voltage) charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
Charger
Ammeter
Adjust the voltage to obtain the
standard charging amperage.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “CHECKING AND
CHARGING THE BATTERY”.
Adjust the charging voltage to
20
~
25 V.
Monitor the amperage for 3
~
5 minutes. Is the standard
charging amperage exceeded?
If the amperage does not
exceed the standard charging
amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check the
charging amperage after 5 hours. If there is any change in the amperage,
readjust the voltage to obtain the standard charging amperage.
Leave the battery unused for more than 30 minutes before measuring its
open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
NOTE:
Leave the battery unused for more
than 30 minutes before measuring
its open-circuit voltage.
NOTE:
Set the charging voltage to 16
~
17 V. (If the charging voltage is
lower, charging will be insufficient,
if it is higher, the battery will be
over-charged.)
YES
NO
YES
NO
Содержание Rhino 450 YXR45FAV
Страница 1: ...LIT 11616 19 43 2P5 F8197 10 YXR45FAV SERVICE MANUAL ...
Страница 6: ......
Страница 56: ...2 30 SPEC OIL FLOW DIAGRAMS 1 Oil filter cartridge 2 Oil pipe adapter 3 Oil delivery pipe A A A A 1 1 2 3 ...
Страница 57: ...2 31 SPEC OIL FLOW DIAGRAMS 1 Oil delivery pipe 2 Oil pump 3 Oil strainer A A A A 1 2 3 ...
Страница 347: ...9 4 ELEC CHECKING THE SWITCHES ...
Страница 375: ...9 32 ELEC LIGHTING SYSTEM ...
Страница 411: ......
Страница 412: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...