9 - 18
–
+
ELEC
EB803020
TROUBLESHOOTING
Procedure
Check:
1. Fuses (main, ignition, signaling system)
2. Battery
3. Starter motor
4. Starter relay
5. Main switch
6. Neutral switch
7. Brake light switch
8. Diode 1
9. Wiring connection (the entire starting sys-
tem)
IF THE STARTER MOTOR FAILS TO OPERATE:
NOTE:
• Remove the following part(s) before trouble-
shooting:
1) Console
• Use the following special tool(s) for trouble-
shooting.
Pocket tester
P/N. YU-03112-C, 90890-03112
EB802011
CONTINUITY
1. Fuses (main, ignition, signaling system)
Refer to “CHECKING THE SWITCHES”.
NO CONTINUITY
Replace the fuse.
EB802012
CORRECT
2. Battery
• Check the battery condition.
Refer to “CHECKING AND CHARGING
THE BATTERY” in chapter 3.
Open-circuit voltage
12.8 V or more at 20 °C (68 °F)
*
INCORRECT
• Clean the battery terminals.
• Recharge or replace the battery.