ELEC
L-200
SIGNAL SYSTEM
5. VOLTAGE
• Connect the Multimeter (DC20V) to the
Bulb Socket connector
• Turn the Main Switch to ‘ON’
• Turn the Turn Switch to left or right
• Check for voltage (12V) on the “Chocolate”
lead and “Dark green” at the Flasher Light
terminal.
At flasher light (LH)
Multimeter (+) lead Ÿ Chocolate Terminal ¿
Multimeter (-) lead Ÿ Body earth Á
At flasher light (RH)
Multimeter (+) lead Ÿ Dark Green Terminal À
Multimeter (-) lead Ÿ Body earth Á
MEETS
SPECIFICATIONS
Wiring connection
Wiring circuit from the Turn Switch to Bulb
Socket connector is faulty. Repair/Replace
Refer to “CIRCUIT DIAGRAM”.
OUT OF SPECIFICATION
This circuit is O.K.
4. FLASHER RELAY
• Connect the Multimeter (DC20V) to the
flasher relay coupler
• Turn Main switch to ‘ON’
• Check for voltage (12V) on “Brown/White”
lead at Flasher Relay and (-) terminal body
earth
Multimeter (+) lead Ÿ Brown/White Terminal ¿
Multimeter (-) lead Ÿ Black Terminal À
MEETS
SPECIFICATION
OUT OF SPECIFICATION
The Flasher Relay is faulty. Replace.
7-19
æ