ELEC
L-188
5. SENSOR COIL RESISTANCE
• Disconnect the sensor Coil Coupler from
the Wiring Harness
• Connect the Multimeter (
Ω
X 100) to the
sensor coil coupler
• Check the sensor coil resistance
Mutimeter (+) lead Ÿ Blue/Yellow terminal ¿
Multimeter (-) lead Ÿ Green tertminal À
Replace the Sensor Coil Assembly
OUT OF SPECIFICATION
MEETS
SPECIFICATION
Sensor coil is OK
6. CHARGING COIL RESISTANCE
• Remove the Charging Coil coupler from the
Wire Harness
• Connect the Multimeter to the charging coil
• Measure the charging coil resistance
MEETS
SPECIFICATIONS
Charging coil is OK
Multimeter (+) lead Ÿ White Terminal ¿
Multimeter (-) lead Ÿ Black Terminal À
Replace the Charging CoiL
OUT OF SPECIFICATION
IGNITION SYSTEM/ CHARGING SYSTEM
7-7
Sensor coil resistance :
240
Ω
Ω
Ω
Ω
Ω
± 20 % (at 20ºC)
Charging coil resistance
0.82
Ω
Ω
Ω
Ω
Ω
± 20 % (at 20ºC)
æ