8-49
–
+
ELEC
RADIATOR FAN MOTOR
1. Disconnect:
• Radiator fan motor coupler
2. Connect:
• Battery
(to the radiator fan motor coupler)
3. Inspect:
• Radiator fan motor
Does not move
→
Replace the radiator fan
motor.
Positive battery terminal
→
Blue
1
Negative battery terminal
→
Black
2
RADIATOR FAN MOTOR RELAY
1. Remove:
• Radiator fan motor relay
Inspection steps:
• Connect the pocket tester (
Ω
× 1) and battery
(12 V) to the radiator fan motor relay terminals
as shown.
• If radiator fan motor relay does not have conti-
nuity between the brown/black and blue termi-
nals, replace it.
Positive battery terminal
→
Red/White
1
Negative battery terminal
→
Green/Yellow
2
Positive tester probe
→
Brown/Black
3
Negative tester probe
→
Blue
4